CONNECTOR 47 WAYS ABS FOR CONTACTS
MICRO-TIMER II AND STANDARD-POWER-TIMER
3 to 7Rev. F
108-15225
3.1. Requirements and tests
GENERAL EXAMINATION
TEST REF.PROCEDURE REQUIREMENT
GENERAL EXAMINATION Examination with the naked eye No harming defect
ELECTRICAL TESTS
TEST REF.PROCEDURE REQUIREMENT
CONTACT RESISTANCE mV level method :
Voltage test : ≤ 20 mV
Test current : ≤ 50 mA
SPT Rc ≤ 4mΩ
µT2 : Rc ≤ 6mΩ
Specified current method:
Voltage test ≤ 12 V
Test current : 5 A/mm2
SPT : Rc ≤ 4mΩ
µT2 : Rc ≤ 6mΩ
ISOLATION RESISTANCE Voltage test : 100 Vcc
Between each contact during 1 minute Ri : > 100 MΩ
WITHSTANDING VOLTAGE Voltage test : 1000 Vca
50 Hz between each the contacts and
other contact connected to the mass.
Duration 1 min.
No breakdown
No starting of arc
MECANICAL TEST
TEST REF.PROCEDURE REQUIREMENT
CONTACT INSERTION FORCES IN
HOUSING
Manual insertion (double locking inactive)
- double locking active
SPT : F ≤ 25 N for wire ≤ 3 mm2
SPT : F ≤ 35 N for wirel > 3 mm2
µT2 : F ≤ 25 N
µT2 : F ≥ 50 N
SPT : F ≥ 70 N
CONTACTS RETENTION
IN INSULATOR
Apply to each contact a thrust load :
Inactive secondary lock :
Active secondary lock :
SPT ≥ 100 N
µT2 ≥ 80 N
SPT ≥ 120 N
µT2 ≥ 100 N
POLARIZATION AND CODING DEVICE On a couple connector base plate of cod-
ing and/or different polarity Apply gradu-
ally, at the speed of 50 mm/min, a load
until the value of 200 N is reached.
To maintain during 10s. To release
No the possible coupling of the connectors
CONNECTORS LOCKING EFFECTIVE-
NESS
Apply gradually, at the speed of 50 mm/
min, a load until the value of 200 N is
reached. To maintain during 10s.
To release.
No the defect harming the correct opera-
tion
RECEPTACLE HOUSING COMPO-
NENTS RETENTION
Must resist to 20 operations