MAX. No. of PSUs
on 16A CIRCUIT
2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC
SPECIFICATION
MODEL LPV -150-12 LPV-150-15 LPV -150-24 LPV-150-36 LPV-150-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT
(Typ.)
LEAKAGE CURRENT
SAFETY
STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
12V 15V 24V 36V 48V
10A 8A 6.3A 4.2A 3.2A
0 ~ 10A 0 ~ 8A 0 ~ 6.3A 0 ~ 4.2A 0 ~ 3.2A
120W 120W 151.2W 151.2W 153.6W
200mVp-p 200mVp-p 200mVp-p 200mVp-p 200mVp-p
±1.0%
LPV-150: 180 ~ 305VAC 254 ~ 431VDC; LPVL-150: 90~132VAC
47 ~ 63Hz
87%
±2.0%
±5.0%
88% 89% 89% 90%
13.5 ~ 18V 17 ~ 25V 27 ~ 35V 40 ~ 49V 52 ~ 63V
LPV-150: 1.7A/230VAC 1.5A/277VAC; LPVL-150: 3.0A/115VAC
COLD START 60A(twidth=900 s measured at 50% Ipeak) at 230VACμ
LPV-150: 0.25mA / 240VAC LPVL-150:0.25mA / 120VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2 Class A( 80 load), EN61000-3-3, EAC TP TC 020≤%
Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, light industry level, criteria A, EAC TP TC 020
-25 ~ +65 (Refer to "Derating Curve")℃
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
703Khrs min. MIL-HDBK-217F (25 )℃
191*63*37.5mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC(115VAC for LPVL) input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8. Suitable for indoor use or outdoor use without direct sunlight exposure.
9. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
10. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
LPV-150: 0.74Kg;20pcs/15.8Kg/0.95CUFT; LPVL-150: 0.85Kg;20pcs/17Kg/0.95CUFT
Protection type : Shut down o/p voltage, re-power on to recover
150W Single Output Switching Power Supply LPV-150 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH℃
File Name:LPV,LPVL-150-SPEC 2018-09-30
LPV-150: 18ms/230VAC 20ms/277VAC at full load; LPVL-150: 10ms/115VAC at full load
LPV-150: 500ms, 50ms / 230VAC 500ms, 50ms / 277VAC; LPVL-150: 1500ms, 50ms / 115VAC
±℃ ℃ ℃0.03%/ (0 ~ 40 for LPV-150-12,15 and LPVL-150-12,24;0~50 for LPV-150-24,36,48)
EMC IMMUNITY
EMC EMISSION
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
UL8750,CSA C22.2 No 250.13-12 UL879,CSA C22.2 No.207-M89,BIS IS15885(for LPV-150-12,24 only),,EAC TP TC 004,
IP67 approved. Design refer to EN60950-1
COLD START 75A(twidth=900 s measured at 50% Ipeak) at 115VACμ
Blank type
L type
Blank type
L type
BREAKER 1 units (circuit breaker of type B) / 2 units (circuit breaker of type C) at 115VAC
Blank type
L type Compliance to FCC part 15
L type
Blank type
Design refer to IEC61000-4-2,3,4,5,6,8,11; light industry level, criteria A
Blank type
L type UL8750(type”HL”),CSA C22.2 No 250.13-12 UL879,CSA C22.2 No.207-M89,IP67 approved,