Rev. 2.19.09_167 PTH12030 Series of 6 Embedded Power for Business-Critical Continuity Rev. 3.10.09_167 PTH12030 Series of 5 PTH12030 12 Vin Total Power: # of Outputs: 143 Watts Single Specifications Input Special Features Input voltage range: (See Note 3, page 3) 10.2 - 13.8 Vdc * 26 A output current * 12 V input voltage * Wide-output voltage adjust * 1.2 Vdc to 5.5 Vdc for suffix `W' and 0.8 Vdc to 1.8 Vdc for suffix `L' * Auto-trackTM sequencing* * Margin up/down controls * Efficiencies up to 94.5% * Output ON/OFF inhibit * Output voltage sense * Point-of-Load-Alliance (POLA) compatible * Available RoHS compliant * 2 Year Warranty Input current: No load 10 mA typ. Remote ON/OFF: (See Note 1, page 3) Positive logic 1 V/ms Undervoltage lockout: 8.5 - 9.5 V typ. Track input voltage: * UL/cUL CAN/CSA-C22.2 No. 60950-1-03/UL 60950-1, File No. E174104 (EN60950) Certificate No. B 04 06 38572 044 * CBReport and Certificate to IEC60950, Certificate No. US/8292/UL Pin 11 (See Note 6, page 3) 0.3 Vin Suffix `-W' Suffix `-L' 1.2 - 5.5 Vdc 0.8 - 1.8 Vdc Output Voltage adjustability: (See Note 4, page 3) Setpoint accuracy: 2.0% Vo Line regulation: 5 mV typ. Load regulation: 5 mV typ. Total regulation: 3.0% Vo Minimum load: 0A Ripple and noise: 20 MHz bandwidth (See Note 8, page 3) Temperature co-efficient: Safety * TUV Product Service Start-up time: Suffix `-W' Suffix `-L' 25 mV pk-pk 15 mV pk-pk -40 C to +85 C 0.5% Vo Transient response: (See Note 5, page 3) 50 s recovery time Margin adjustment: 5.0% Vo Overshoot/undershoot 150 mV All specifications are typical at nominal input, full load at 25 C unless otherwise stated Cin = 560 F, Cout = 0 F *Auto-trackTM is a trade mark of Texas Instruments Embedded Power for Business-Critical Continuity Rev. 3.10.09_167 PTH12030 Series of 5 Specifications Continued EMC Characteristics Electrostatic discharge: EN61000-4-2, IEC801-2 Conducted immunity: EN61000-4-6 Radiated immunity: EN61000-4-3 General Specifications Efficiency: See efficiency table on page 3 Insulation voltage: Non-Isolated Switching frequency: Approvals and standards: Over Vin and Io ranges EN60950, UL/cUL60950 Material flammability: Dimensions: UL94V-0 (L x W x H) Weight: MTBF: 575 kHz typ. 34.80 x 28.45 x 9.00 mm 1.370 x 1.120 x 0.354 in 7g (0.25 oz) Telcordia SR-332 2,821,000 hours Environmental Specifications Thermal performance: (See Note 2, page 3) Operating ambient, temperature Non-operating -40 C to +85 C -40 C to +125 C MSL (`Z' suffix only): JEDEC J-STD-020C Level 3 Protection Short circuit: Thermal: Auto reset 40 A typ. Auto recovery Embedded Power for Business-Critical Continuity Rev. 3.10.09_167 PTH12030 Series of 5 Ordering Information Output Power (max) Input Voltage Output Voltage 143 W 10.2 - 13.8 Vdc 143 W 10.2 - 13.8 Vdc Output Currents Min Max Efficiency (max) 0.8 - 1.8 Vdc 0A 26 A 89% 5 mV 5 mV PTH12030L 1.2 - 5.5 Vdc 0A 26 A 94.5% 5 mV 5 mV PTH12030W Part Number System with Options Regulation Line Load M odel Numbers (9, 10) PTH12030WAST Product Family Point of Load Alliance Compatible Packaging Options No Suffix = Trays T = Tape and Reel (8) Input Voltage 12 = 12 V Mounting Option (9) D = Horizontal Through-Hole (RoHS 6/6) H = Horizontal Through-Hole (RoHS 5/6) S = Surface-Mount Solder Ball (RoHS 5/6) Z = Surface-Mount Solder Ball (RoHS 6/6) Output Current 03 = 26 A Pin Option A= Through-Hole Std. Pin Length (0.140") A = Surface-Mount Tin/Lead Solder Ball Mechanical Package Always 0 Output Voltage Code W = Wide, L = Low Voltage Output Voltage Adjustment of the PTH12030 Series The ultra-wide output voltage trim range offers major advantages to users who select the PTH12030. It is no longer necessary to purchase a variety of modules in order to cover different output voltages. The output voltage can be trimmed in a range of 1.2 Vdc to 5.5 Vdc for suffix `W' and 0.8 Vdc to 1.8 Vdc for suffix `L'. When the PTH12030 converter leaves the factory the output has been adjusted to the default voltage of 1.2 V for the PTH12030W and 0.8 V for the PTH12030L. Efficiency Table - PTH12030W (Io = 18 a) Output Voltage Efficiency Vo = 5.0 V 94.5% Vo = 3.3 V 92.7% Vo = 2.5 V 91.4% 1 2 Vo = 2.0 V 90.3% 3 Vo = 1.8 V 89.5% 4 Vo = 1.5 V 88.2% Vo = 1.2 V 86.2% Efficiency Table - PTH12030L (Io = 18 a) Output Voltage Efficiency Vo = 1.8 V 89% Vo = 1.5 V 87% Vo = 1.2 V 85% Vo = 1.0 V 83% Vo = 0.8 V 80% Notes 5 6 7 8 9 9 Remote ON/OFF. Active High ON: Pin 4 open; or V >Vin - 0.5 V OFF: Pin 4 GND; or V <0.8 V (min - 0.2 V). See Figure 1 for safe operating curve of the PTH12030W and Figure 4 for safe operating curve of PTH12030L. A 560 F electrolytic input capacitor is required for proper operation. The capacitor must be rated for a minimum of 800 mA rms of ripple current. An external output capacitor is not required for basic operation. Adding 330 F of distributed capacitance at the load will improve the transient response. 1 A/s load step, 50 to 100% Iomax, Cout = 330 F. If utilized Vout will track applied voltage by 0.3 V(up to Vo set point). Tape and reel packaging only available on the surface-mount versions. The pk-pk output ripple voltage is measured with an external 10 F ceramic capacitor. See Figure 3 Standard application schematic on the following page. To order Pb-free (RoHS compatible) surface-mount parts replace the mounting option `S' with `Z', e.g. PTH12030WAZ. To order Pb-free (RoHS compatible) through-hole parts replace the mounting option `H' with `D', e.g. PTH12030WAD. NOTICE: Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search tool at http://www.PowerConversion.com to find a suitable alternative. Embedded Power for Business-Critical Continuity Rev. 3.10.09_167 PTH12030 Series of 5 PTH12030W Characteristic Data 80 100 70 60 EFFICIENCY (%) TEMPERATURE (C) 90 Nat Conv 100 LFM 200 LFM 400 LFM 50 40 30 80 Vout 1.2V 1.8V 2.5V 3.3V 5.0V 60 40 20 0 4 8 12 16 20 0 24 4 8 OUTPUT CURRENT (A) 12 16 20 24 OUTPUT CURRENT (A) Figure 2 - Efficiency vs Load Current Vin = 12 V (See Note B) Figure 1 - Safe Operating Area Vin = 12 V, Output Voltage = 3.3 V (See Note A) PTH12030W Characteristic Data 100 80 90 EFFICIENCY (%) TEMPERATURE (C) 90 70 60 Nat conv 100 LFM 200 LFM 400 LFM 50 40 30 20 70 60 50 0 5 10 15 20 Vout 1.8V 1.5V 1.2V 1.0V 0.8V 80 25 OUTPUT CURRENT (A) 0 5 10 15 20 25 OUTPUT CURRENT (A) Figure 3 - Safe Operating Area Vin = 12 V, Output Voltage 1.8 V (See Note A) Figure 4 - Efficiency vs Load Current Vin = 12 V (See Note B) Track Margin Down Margin Up 13 12 11 10 1 Vin 2 9 PTH12030 (Top View) 7 3 4 Inhibit 5 6 Vo Sense Cin 560F (Required) Notes Vout 8 + RSET 0.5%, 0.1W (Required) Cout 330F (Optional) + GND GND Figure 5 - Standard Application - All Models L O A D A SOA curves represent the conditions at which internal components are within the Emerson Network Power derating guidelines. B Characteristic data has been developed from actual products tested at 25 C. This data is considered typical data for the converter. Embedded Power for Business-Critical Continuity Mechanical Drawings 0.060 (1.52) 0.125 (3.18) Americas 1.370 (34.80) 0.125 (3.18) 0.125 (3.18) 0.500 (12.70) 0.060 (1.52) 0.500 (12.70) o0.040 (1.02) 13 Places 10 13 12 11 1 0.140 (3.55) 2 9 8 0.375 (9.52) Lowest Component 0.010 min. (0.25) Bottom side Clearance 1.120 (28.45) 0.125 (3.18) 0.375 (9.52) 3 4 5 6 (0.070 (1.78) (Standoff Shoulder) 7 TOP VIEW Host Board 0.354 (9.00) max. Dimensions in Inches (mm) Tolerances (unless otherwise specified) 2 Places 0.030 (0.76) 3 Places 0.010 (0.25) SIDE VIEW 0.060 (1.52) 0.125 (3.18) 13 12 11 1 0.354 (9.00) max.* 0.060 (1.52) 0.500 (12.70) *After solder reflow on customer board 10 9 8 Solder Ball o0.040 (1.02) 13 Places 1.120 (28.45) 0.125 (3.18) 4 5 6 Emerson Network Power. The global leader in enabling business-critical continuity. Connectivity DC Power Embedded Computing 7 TOP VIEW Embedded Power SIDE VIEW Monitoring Dimensions in Inches (mm) Tolerances (unless otherwise specified) 2 Places 0.030 (0.76) 3 Places 0.010 (0.25) Outside Plant Power Switching & Controls Figure 7 - Surface-Mount Pin Connections While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. AC Power 0.375 (9.52) 3 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone:+852 2176 3333 Facsimile: +852 2176 3888 www.PowerConversion.com 0.500 (12.70) 0.375 (9.52) Asia (HK) techsupport.embeddedpower @emerson.com 0.375 (9.52) 2 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone:+44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 For global contact, visit: Figure 6 - Plated Through-Hole 1.370 (34.80) 0.125 (3.18) 0.125 (3.18) 0.500 (12.70) 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone:+1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) 0.500 (12.70) 0.375 (9.52) Rev. 3.10.09_167 PTH12030 Series of 5 Pin Connections cont. Pin Connections cont. Precision Cooling Racks & Integrated Cabinets Services Pin No. Function Pin No. Function Pin No. Function Pin 1 Ground Pin 6 Vo sense Pin 11 Track Pin 2 Vin Pin 7 Ground Pin 12 Margin down* Pin 3 Ground Pin 8 Vout Pin 13 Margin up* Pin 4 Inhibit* Pin 9 Vout Pin 5 Vo adjust Pin 10 Ground * Denotes negative logic: Open = Normal operation Ground = Function active Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. (c)2008 Emerson Electric Co.