5
E3Z-TAE3Z-TA
■Wiring
Power Supply Voltage
Make sure that the power supply to the Sensor is within the rated
voltage range.
Load Short-Circuiting
Do not short-circuit the load, or the Sensor may be damaged.
Polarity
Correct polarity wiring is required to prevent damage to the sensor.
Connection without Load
Do not connect the power supply to the Sensor when no load
is connected, or the internal elements may explode or burn.
■Operating Environment
Do not use the Sensor in locations with explosive or flammable
gas.
■Settings
Power Reset Time
When the E3Z-TA is turned ON, there is a 100 ms delay time
before operation. If the load and the Sensor are connected to
independent power supplies, be sure to turn ON the sensor before
turning ON the load.
■Connections
M8 Metal Connector
• Turn OFF the power before disconnecting the sensor.
• Remove the connector cover before connecting or disconnecting
the metal connector.
• Secure the connector cover by hand. Do not use pliers, or the
connector may be damaged.
• The proper tightening torque range is between 0.3 and 0.4 N"m.
To ensure safe sensor operation, please follow these precautions.
E3Z-TA
(bracket sold separately)
■Mounting and Adjusting Slits
• Hook the upper protruding portion of the Slit to the upper
indented mounting portion of the Sensor and adjust the
position of the Slit so that the Slit will be parallel to
the lens side of the Sensor. (See area 1, in the
illustration below.)
• Then, press the lower protruding portion of the Slit onto
the indented mounting portion of the Sensor until the Slit
snaps in. (See area 2, shown below.)
Removal Method
• Press the upper portion of the Slit. (See area 1, shown below.)
• Then, disconnect the lower protruding portion of the Slit from the
Sensor and remove the Slit. (See area 2, shown below.)
Side view
Front view
Slit
Sensor
• Mounting views
Upper indented
Hook mounting portion
Protruding
portion
1
2
1
mounting portion
Lower indented
Precautions
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. CEDSAX4 Printed in USA
OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V8
416-286-6465
OMRON ELECTRONICS LLC
One East Commerce Drive
Schaumburg, IL 60173
1-800-55-OMRON
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.com/oci
11/01 Specifications subject to change without notice