July 2004
PG01200002E For more information visit: www.EatonElectrical.com
1
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Sizes EG through RG (15 – 2500 Amperes)
Vol. 1, Ref. No. [01]
Description Page
Standards . . . . . . . . . . . . . . . .
1
General Information . . . . . . . .
2
Typical Applications . . . . . . . .
3
Electrical Characteristics . . . .
4
Multi-Function
Electronic Trip Units . . . . . . .
10
Electronic Trip Unit
Selection Guide . . . . . . . . . .
12
Breaker Ordering Information/
Catalog Numbers/
Termination Accessories
EG-Frame,
15 – 160 Amperes . . . . . .
13
JG-Frame,
20 – 250 Amperes . . . . . .
17
LG-Frame,
100 – 630 Amperes . . . . .
21
NG-Frame,
400 – 1200 Amperes . . . .
25
NG-Frame,
1600 Amperes . . . . . . . . .
28
RG-Frame,
800 – 2500 Amperes . . . .
29
Motor Circuit Protectors . . . . .
33
30 mA Ground Fault
(Earth Leakage) Modules . . .
34
Special Features
and Accessories . . . . . . . . . .
35
Plug-in Blocks &
Drawout Cassette . . . . . . . . .
38
Handle Mechanisms . . . . . . . .
39
Time Current Curves . . . . . . . .
42
Current Limiting Curves . . . . .
50
Dimensions . . . . . . . . . . . . . . .
51
Standards
Cutler-Hammer
T
Molded Case Circuit
Breakers from Eaton Electrical’s
business are designed to conform
with the following international
standards:
Australian Standard AS 2184 and
AS 3947-2 Molded Case Circuit
Breakers.
British Standards Institution
Standard BS 4752: Part 1, Switch-
gear and Control Gear Part 1,
Circuit Breakers.
International Electrotechnical
Commission Recommendations
IEC 60947.2 Circuit Breakers.
Japanese T-Mark Standard
Molded Case Circuit Breakers.
National Electrical Manufacturers
Association Standards Publication
No. AB1-1975 Molded Case
Circuit Breakers.
South African Bureau of Standards,
Standard SABS 156, Standard
Specification for Molded Case
Circuit Breakers.
Swiss Electro-Technical Association
Standard SEV 947.2, Safety
Regulations for Circuit Breakers.
Union Technique de l’Electricite
Standard NF C 63-120, Low Voltage
Switchgear and Control Gear
Circuit Breaker Requirements.
Verband Deutscher Elektrotechnike
(Association of German Electrical
Engineers) Standard VDE 0660,
Low Voltage Switchgear and
Control Gear, Circuit Breakers.
Trademarks
Cutler-Hammer is a federally regis-
tered trademark of Eaton Corporation.
CSA is a registered trademark of
Canadian Standards Association.
UL is a registered trademark of
Underwriters Laboratories Inc.
ISO is the registered trademark and
sole property of the International
Organization for Standardization.
NEMA is the registered trademark and
service mark of the National Electrical
Manufacturers Association.
Global Third Party
Certification
Certification marks ensure product
compliance with the total standard
via the third party witnessing of tests
by globally recognized independent
certification organizations.
KEMA is a highly recognized, indepen-
dent international organization that
offers certification and inspection
facilities for equipment in many
industries. The KEMA-KEUR mark is
the highest certification an electrical
product can receive from KEMA.
Our IEC 60947-2 Molded Case Circuit
Breakers are KEMA tested and certi-
fied. These breakers are also listed
in accordance with UL
T
489, as well
as CSA C22.2 No. 5-02.
KEMA and UL provide ongoing
follow-up testing and inspections to
ensure that Cutler-Hammer Molded
Case Circuit Breakers continue to meet
their exacting standards.
July 2004
2
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Sizes EG through RG (15 – 2500 Amperes)
Vol. 1, Ref. No. [02]
General Information
Cutler-Hammer Series G Molded Case
Circuit Breakers provide increased
performance in considerably less
space than standard circuit breakers
or comparable fusible devices.
The “G” signifies global applications:
Series G circuit breakers are marked
with UL, CSA
T
, CE, IEC and KEMA
KEUR listings. Other advantages
include:
Field-fit accessories.
Common accessories through
630 amperes.
Electronic trip units from 20 to
2500 amperes.
UL-listed and IEC-rated, 30 mA
ground fault/earth leakage modules.
Built-in ground fault protection
down to 20 amperes.
The EG, JG and LG frames are new
circuit breakers designed around
space-saving footprints. The NG and
RG use the proven Cutler-Hammer
Series C
T
ND and RD designs but use
metric threading on their line and
load conductors.
Cutler-Hammer Series G Circuit
Breakers meet applicable UL 489
and IEC 60947-2 standards.
The Cutler-Hammer Series G family
includes five frame sizes in ratings
from 15 to 2500 amperes. Series G
offers a choice of several interrupting
capacities up to 100 kA at 480 volts ac
(200 kA at 240 volts ac).
Standard calibration is 40°C. For appli-
cations in high ambient temperature
conditions, 50°C factory calibration
is available on thermal magnetic
breakers.
The Most Logically Designed
Contact Assembly
The flexibility and outstanding
performance characteristics of Cutler-
Hammer Circuit Breakers are made
possible by the best contact designs
in circuit breaker history. Our patented
technology creates a high-speed
“blow-open” action using the
electromechanical forces produced
by high-level fault currents.
Cutler-Hammer Circuit Breakers are
operated by a toggle-type mechanism
that is mechanically trip-free from
the handle so that the contacts cannot
be held closed against short circuit
currents. Tripping due to overload or
short circuits is clearly indicated by the
position on the handle. This remark-
ably fast and dependable contact
action is designed to enhance safety.
Thorough In-Plant Testing
The quality, dependability and reliability
of every Cutler-Hammer Circuit Breaker
is ensured by a thorough program
of in-plant testing. Two calibration
tests are conducted on every pole of
every circuit breaker to verify the trip
mechanism, operating mechanism,
continuity and accuracy.
ISO Certification
Cutler-Hammer Circuit Breakers
are manufactured in ISO
T
certified
facilities.
Current Limiting Characteristics
Cutler-Hammer Series G Circuit
Breakers are current limiting because
of their high repulsion contact
arrangement and use of state-of-
the-art arc extinguishing technology.
Operating Mechanisms
Cutler-Hammer Circuit Breakers have
a toggle handle operating mechanism,
which also serves as a switching
position indicator. The indicator shows
the positions of: ON, OFF and TRIPPED.
The toggle handle snaps into the
TRIPPED position if the breaker is
tripped by one of its overcurrent, short
circuit, shunt or undervoltage releases.
Before the circuit breaker can be
reclosed following a trip-out, the tog-
gle handle must be brought beyond
the OFF position (RESET). The circuit
breaker can then be reclosed.
As an additional switching position
indicator for EG- to RG-Frame circuit
breakers, there are two windows on
the right and on the left of the toggle
handle, in which the switching state
is indicated by means of the colors
red, green and white corresponding to
the ON, OFF and TRIPPED positions
respectively.
Figure 1. Positions of the Toggle Handle Drive
OFF
RESET
ON Tripped
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
3
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Sizes EG through RG (15 – 2500 Amperes)
Vol. 1, Ref. No. [03]
Typical Applications
Machine Tool Control Panels
and Motor Control Centers
Designed for these equipment
requirements, including new
world-class accessories.
Panelboards
As both main and branch circuit
protection devices.
Feeder Pillars
In distribution systems to provide
main and branch circuit protection.
Switchgear
In distribution systems to provide
main and branch circuit protection up
to 2500 amperes (RG-Frame).
Bus Bar Trunking Tap-Offs
In bus bar trunking tap-offs to provide
circuit protection.
Individual Enclosures
Completely assembled in enclosures
to meet specific customer
requirements.
Additional Applications
Special versions of each Cutler-Hammer
frame are available to provide safe
equipment control and protection in
mining and other applications. Contact
your Eaton agent or distributor for
additional information.
Figure 2. Typical Cutler-Hammer Applications
Table 1. Typical Cutler-Hammer Applications
1
125 amperes is the maximum UL and CSA rating for the EG.
2
630 amperes is not a UL or CSA listed rating. 600 amperes is the maximum UL and CSA rating
for the LG.
3
1200 amperes is the maximum UL and CSA rating for the NG.
Frame Continuous
Ampere
Rating
Range
Trip Unit Type Molded
Case
Switch
Adjustable
Thermal
Fixed
Magnetic
Fixed
Thermal
Fixed
Magnetic
Adjustable
Thermal
Adjustable
Magnetic
30 mA
Ground
Fault/Earth
Leakage
Digitrip
e
RMS
Electronic
Trip Units
E 15 – 160
1
■■
J 20 – 250
■■
L 100 – 630
2
——
■■■■
N 400 – 1600
3
————
■■
R 800 – 2500 ————
■■
Switchboard
Machine Tool
Control Panel
Bus Bar
Trunking
Tap-Off
Individual
Circuit
Breaker
Enclosure
Panelboard
July 2004
4
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Sizes EG through LG
Vol. 1, Ref. No. [04]
Electrical Characteristics
Table 2. Electrical Characteristics
1
125 amperes is the maximum UL and CSA rating for the EG.
2
630 amperes is not a UL or CSA listed rating. 600 amperes is the maximum UL and CSA listed rating for the LG.
3
Contact your Eaton representative for availability prior to December 2004.
4
Two poles in series.
5
Not suitable for dc application. 4-pole ground fault not available.
Maximum Rated Current
(Amperes) EG JG LG
125, 160
1
250 400, 630
2
Breaker Type B E S H E S H C
3
ESHC
3
Number of Poles 1 2, 3, 4 2, 3, 4 1 2, 3, 4 1 2, 3, 4 2, 3, 4 3, 4
Breaker Capacity (kA rms) ac 50 – 60 Hz
NEMA
T
,
UL, CSA 240 Vac 25 25 35 85 85 100 100 65 85 100 200 65 85 100 200
480 Vac 18 25 35 65 25 35 65 100 35 50 65 100
600 Vac ————1825 35 501825 35 50
250 Vdc
4
10 10 10 35 35 42 42 10 35 42 42 22 22 42 42
IEC 60947-2 220 – 240 Vac Icu 25 25 35 85 85 100 100 65 85 100 200 65 85 100 200
Ics 25 25 35 43 43 50 50 65 85 100 150 65 85 100 150
380 – 415 Vac Icu 18 25 40 70 25 40 70 100 35 50 70 100
Ics 18 25 30 35 25 40 70 75 35 50 70 75
660 – 690 Vac Icu 3 4 6 12 12 14 20 12 20 25 35
Ics 3 3 3 6 6 7 10 6 10 13 18
250 Vdc
4
Icu 10 10 10 35 35 42 42 10 35 42 42 22 22 42 42
Ics 10 10 10 35 35 42 42 10 35 42 42 22 22 42 42
Ampere Range 15 – 160 A
1
20 – 250 A 100 – 630 A
2
Trip Units
F= Fixed
A= Adjustable
T= Thermal
M= Magnetic
FT-FM
AT-FM FT-AM
AT-AM
Electronic (Digitrip RMS 310)
FT-AM
AT-AM
Electronic (Digitrip RMS 310)
Interchangeable
■■
Built-in
■■
Thermal
Magnetic Fixed Thermal
■■
Adjustable Thermal
■■
Magnetic Fixed Adjustable Adjustable
Electronic
rms
5
LS
■■
4
LSI
■■
4
LSG
■■
4
LSIG
■■
4
Dimensions
Inches (mm) HWDHWDHWD
1-Pole 5.50
(139.7) 1.00 (25.4) 2.99
(76.0) ——————
2-Pole 2.00 (50.8) 7.00
(177.8)
4.13
(105.0) 3.57
(87.4)
———
3-Pole 3.00 (76.2) 10.13
(258.0) 5.48
(140.0) 4.09
(104.0)
4-Pole 4.00 (101.6) 5.34
(135.6) 7.22
(183.0)
Weight (approximate) lbs. (kg) 1-Pole 2-Pole 3-Pole 4-Pole 2-Pole 3-Pole 4-Pole 3-Pole 4-Pole
1.1 (0.5) 2.0 (0.9) 3.1 (1.4) 3.9 (1.8) 11.4 (5.2) 11.4 (5.2) 15.3 (7.0) 16.0 (7.3) 20.0 (9.1)
Utilization Category A A A
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
5
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Sizes NG and RG
Vol. 1, Ref. No. [05]
Table 2. Electrical Characteristics (Continued)
1
The NG and RG MCCBs use metric threading in their line and load terminals. If English (Imperial) threading is needed, use Series C ND and RD MCCBs.
Contact Eaton for more information.
2
NG 1600 ampere frame is not UL or CSA listed.
3
Not KEMA-KEUR listed.
4
IEC 60947-2 H.5 Annex H is not KEMA-KEUR tested.
5
Not suitable for dc application. 4-pole ground fault not available.
6
Available only on Digitrip 610 and 910 trip units.
Maximum Rated Current
(Amperes) NG
1
RG
1
800, 1200 1600
2
1600, 2000, 2500
Breaker Type S H C
3
SH C
3
Breaker Capacity (kA rms) ac 50 – 60 Hz
NEMA,
UL, CSA 240 Vac 65 100 200 125 200
480 Vac 50 65 100 65 100
600 Vac 25 35 50 50 65
IEC 60947-2 220 – 240 Vac Icu 85 100 200 85 135 200
Ics 85 100 100 85 100 100
380 – 415 Vac Icu 50 70 100 50 70 100
Ics 50 50 50 50 50 50
660 – 690 Vac Icu 20
4
25
4
35 20
4
25
4
35
4
Ics 10 13 18 10 13 18
250 Vdc Icu —————
Ics —————
Number of Poles 2, 3, 4 3 3, 4
Ampere Range 400 – 1200 A 1600 A 800 – 2500 A
Trip Units Electronic (Digitrip RMS 310) Electronic (Digitrip RMS 310, 610 and 910)
Interchangeable
Built-in
Electronic
5
LI
6
LS
LSI
LIG
6
LSG
LSIG
Dimensions
Inches (mm) HWDH W D
1-Pole ————
2-Pole ————
3-Pole 16.00 (406.0) 8.25 (210.0) 5.50 (140.0) 16.00 (406.0) 15.50 (394.0) 9.75 (229.0)
4-Pole 11.13 (280.0) 20.00 (508.0)
Weight (approximate) lbs. (kg) 3-Pole 4-Pole 3-Pole 4-Pole
46.8 (21.3) 62.0 (28.3) 103.0 (47.0) 118.4 (54.0)
Utilization Category A A
July 2004
6
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Sizes EG through RG Vol. 1, Ref. No. [06]
Table 3. EG through RG Electrical Characteristics
1125 amperes is the maximum UL and CSA rating for the EG.
2630 amperes is not a UL or CSA listed rating. 600 amperes is the maximum UL and CSA rating for the LG.
31200 amperes is the maximum UL and CSA rating for the NG.
4See footnotes for exceptions.
5Thermal overload release set to the lower value.
6Thermal overload release set to the upper value.
7Not suitable for dc switching.
Technical Data EG JG LG NG RG
Maximum Rated Current In
Depending on the Version 160 A 1250 A 400, 630 A 2800, 1200, 1600 A 31600, 2000, 2500 A
Rated Insulation Voltage U, According to IEC 60947-2
Main Conducting Paths
Auxiliary Circuits 690 Vac
690 Vac 750 Vac
690 Vac 750 Vac
690 Vac 750 Vac
690 Vac 750 Vac
690 Vac
Rated Impulse Withstand Voltage Uimp
Main Conducting Paths
Auxiliary Circuits 6 kV
4 kV 8 kV
4 kV 8 kV
4 kV 8 kV
4 kV 8 kV
4 kV
Rated Operational Voltage Ue
IEC
NEMA 690 Vac
600 Y/347 Vac 690 Vac
600 Vac 690 Vac
600 Vac 690 Vac
600 Vac 690 Vac
600 Vac
UL and CSA Listed Yes 4Yes 4Yes 4Yes 4Yes 4
Permissible Ambient Temperature -20 to +70°C -20 to +70°C -20 to +70°C -5 to +60°C -5 to +60°C
Permissible Load for Various Ambient Temperatures
Close to the Circuit Breaker, Related to the Rated
Current of the Circuit Breaker
Circuit Breakers for Plant Protection
At 40°C
At 50°C
At 55°C
At 60°C
At 70°C
5
100%
96%
93%
91%
86%
6
100%
92%
87%
83%
73%
5
100%
96%
94%
92%
88%
6
100%
94%
90%
87%
80%
5
100%
96%
93%
90%
84%
6
100%
91%
86%
82%
70%
100%
91%
85%
81%
100%
91%
85%
81%
Circuit Breakers for Motor Protection
At 40°C
At 50°C
At 55°C
At 60°C
At 70°C
100%
100%
100%
100%
90%
100%
100%
100%
100%
90%
Circuit Breakers for Starter Combinations
and Isolating Circuit Breakers
At 40°C
At 50°C
At 55°C
At 60°C
At 70°C
100%
100%
96%
91%
86%
100%
100%
96%
82%
88%
100%
100%
95%
90%
84%
100%
91%
85%
81%
100%
91%
85%
81%
Rated Short Circuit Breaking Capacity (dc)
Not for Circuit Breakers for Motor Protection
(Time Constant t = 10 rms)
2 Conducting Paths in Series
For EG to LG up to 250 Vdc
NEMA (Time Constant t = 8 rms)
2 Conducting Paths in Series
250 Vdc
42 kA Max.
42 kA Max.
42 kA Max.
42 kA Max.
42 kA Max.
42 kA Max.
7
7
7
7
7
7
Main Switch Characteristics According to IEC 60947-2
in Combination with Lockable Rotary Drives Yes Yes Yes Yes Yes
Rated Short Circuit Breaking Capacity According
to IEC 60947-2 (at ac 50/60 Hz) Rated Short Circuit Breaking Capacity See Table 2 on Page 4
Endurance (Operating Cycles) 10,000 10,000 8,000 3,000 3,000
Maximum Switching Frequency 300 1/h 240 1/h 240 1/h 60 1/h 20 1/h
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
7
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Sizes EG through RG
Vol. 1, Ref. No. [07]
Table 3. EG through RG Electrical Characteristics (Continued)
Technical Data EG JG LG NG RG
Conductor Cross Sections and Terminal Types
for Main Conductors
Solid or Stranded
Finely Stranded with End Sleeve
Bus Bar
Tightening Torque for Box Terminals
Tightening Torque for Bus Bar Connection Pieces
Box Terminals
2.5 to 95 mm2
2.5 to 50/70 mm2
5.6 Nm
5.6 Nm
Box Terminals
50 to 150 mm2
35 to 120 mm2
20 Nm
15 Nm
Box Terminals
95 to 240 mm2
70 to 150 mm2
42 Nm
30 Nm
Flat Bar
Terminals
600 A
31 Nm
6 Nm
Flat Bar Terminals
Optional
31 Nm
50 Nm
Flat Bar Terminals
Optional
20 Nm
Conductor Cross Sections for Auxiliary Circuits
with Terminal Connection or Terminal Strip
Solid
Finely Stranded with End Sleeve
With Brought-out Cable Ends
Tightening Torque for Fitting Screws
0.75 to 2.5 mm2
0.75 to 2.5 mm20.75 to 2.5 mm2
0.75 to 2.5 mm2
0.82 (AWG 18) mm2
0.8 to 1.4 Nm
0.75 to 2.5 mm2
0.75 to 2.5 mm2
0.82 (AWG 18) mm2
0.8 to 1.4 Nm
Up to 2x4 mm2
Up to 2x2.5 mm2
0.82 (AWG 18) mm2
0.8 to 1.4 Nm
Up to 2x4 mm2
Up to 2x2.5 mm2
0.82 (AWG 18) mm2
0.8 to 1.4 Nm
Power Loss per Circuit Breaker at Maximum
Rated Current ln (The Power Losses of the
Undervoltage Releases (“r” Releases) Must Be
Observed if Necessary) at Three-Phase
Symmetrical Load)
For Plant Protection
As Isolating Circuit Breaker
For Starter Combinations
For Motor Protection
50 W
40 W
40 W
75 W
75 W
45 W
75 W
255 W
160 W
160 W
120 W
87/210 W
87/210 W
220/270/400 W
220/270/400 W
Permissible Mounting Position
Arc Spacing —
Suitable for Reverse-Feed Applications Yes
(Except HMCPE) Yes Yes Yes Yes
90°
90°
90°
90°
July 2004
8
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Sizes EG through RG Vol. 1, Ref. No. [08]
Table 3. EG through RG Electrical Characteristics (Continued)
Technical Data EG JG LG NG RG
Auxiliary Switches
Rated Thermal Current lth
Rated Making Capacity 6 A
20 A 6 A
20 A 6 A
20 A 6 A
20 A 6 A
20 A
ac (ac-15)
Rated Operational Voltage
Rated Operational Current 230/400/600 V
6/3/0.25 A 230/400/600 V
6/3/0.25 A 230/400/600 V
6/3/0.25 A 600 V
6 A 600 V
6 A
dc (dc-13)
Rated Operational Voltage
Rated Operational Current 125/250 V
0.5/0.25 A 125/250 V
0.5/0.15 A 125/250 V
0.5/0.15 A 125/250 V
0.5/0.25 A 125/250 V
0.5/0.25 A
Backup Fuse
Miniature Circuit Breaker 6/4/4 A
6/4 A 4
6/4/4 A
6/4 A
4
6/4/4 A
6/4 A
4
6/4/4 A
6/4 A
4
6/4/4 A
6/4 A
Releases
Undervoltage Releases (“r” Releases)
Response Voltage:
Drop (Breaker Tripped) Us
Pickup (Breaker May Be Switched on) Us
35 – 70%
85 – 110% 35 – 70%
85 – 110% 35 – 70%
85 – 110% 35 – 70%
85 – 110% 35 – 70%
85 – 110%
Power Consumption in Continuous Operation at:
50/60 Hz 12 Vac
50/60 Hz 24 Vac
50/60 Hz 48 – 60 Vac
50/60 Hz 110 – 127 Vac
50/60 Hz 208 – 240 Vac
50/60 Hz 380 – 500 Vac
50/60 Hz 525 – 600 Vac
12 Vdc
24 Vdc
48 – 60 Vdc
110 – 125 Vdc
220 – 250 Vdc
Maximum Opening Time
0.95 VA
0.72 VA
1.15 – 1.78 VA
0.96 – 1.25 VA
1.28 – 1.68 VA
2.2 – 3.9 VA
3.4 – 4.3 VA
0.88 W
0.70 W
1.12 – 1.76 W
0.94 – 1.21 W
1.45 – 1.86 W
50 ms
1.9 VA
3.9 VA
2.5 – 3.8 VA
1.8 – 2.4 VA
2.7 – 3.8 VA
3.4 – 5.8 VA
3.4 – 4.3 VA
1.6 W
3.1 W
2.0 – 3.1 W
1.6 – 2.2 W
3.1 – 4 W
50 ms
1.9 VA
3.9 VA
2.5 – 3.8 VA
1.8 – 2.4 VA
2.7 – 3.8 VA
3.4 – 5.8 VA
3.4 – 4.3 VA
1.6 W
3.1 W
2.0 – 3.1 W
1.6 – 2.2 W
3.1 – 4 W
50 ms
1.9 VA
2.4 VA
2.3 – 4.1 VA
3.4 – 4.2 VA
4.8 – 6.5 VA
6.8 – 12.0 VA
2.6 W
3.6 W
3.5 – 5.5 W
2.9 – 3.6 W
4.8 – 6.3 W
62 ms
2.9 VA
3.1 VA
3.4 – 6.0 VA
3.3 – 3.8 VA
4.2 – 7.2 VA
3.8 – 10.0 VA
3.4 W
4.3 W
4.8 – 7.2 W
3.3 – 3.8 W
6.6 – 7.5 W
62 ms
Shunt Trips
Shunt Trips (“f” Releases)
Response Voltage:
Pickup (Breaker Tripped) Us 70 – 110% 70 – 110% 70 – 110% 70 – 110% 70 – 110%
Power Consumption in (Short Time) at:
50/60 Hz 24 Vac
50/60 Hz 48 – 60 Vac
50/60 Hz 48 – 127 Vac
50/60 Hz 110 – 240 Vac
50/60 Hz 380 – 440 Vac
50/60 Hz 380 – 600 Vac
50/60 Hz 480 – 600 Vac
12 – 24 Vdc
48 – 60 Vdc
110 – 125 Vdc
220 – 250 Vdc
10 – 41 VA
139 – 210 VA
83 – 360 VA
418 – 1080 VA
29 – 120 W
475 – 720 W
99 – 121 W
87 – 405 VA
710 – 1105 VA
66 – 432 VA
127 – 188 VA
34 – 60 VA
164 – 631 W
830 – 1580 W
112 – 150 W
40 – 58 W
87 – 405 VA
710 – 1105 VA
66 – 432 VA
127 – 188 VA
34 – 60 VA
164 – 631 W
830 – 1580 W
112 – 150 W
40 – 58 W
98 – 475 VA
24 – 50 VA
67 – 432 VA
76 – 110 VA
19 – 42 VA
145 – 610 W
67 – 102 W
121 – 150 W
46 – 55 W
612 VA
403 – 666 VA
396 – 1896 VA
1596 – 2156 VA
230 – 384 VA
396 W
341 – 528 W
264 – 350 W
374 – 475 W
Maximum Load Duration Interrupts Automatically
Maximum Opening Time 50 ms 50 ms 50 ms 62 ms 62 ms
Molded Case Switch (with High Magnetic Trip)
Unfused kAIC at 480 Vac (415 Vac)
Self-Protected, Will Trip Above: 65 (70)
1250 for EG125;
1600 for EG160
65 (70)
2500 65 (70)
4000/6300 65 (70)
12,500 65 (70)
20,000
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
9
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Sizes EG through LG
Vol. 1, Ref. No. [09]
dc Switching Duty
The EG- to LG-Frame circuit breakers
are also suitable for switching dc
currents.
The NG- and RG-Frame circuit break-
ers are not suitable for dc currents
due to the solid-state overcurrent
release system.
For switching dc currents, however,
the maximum permissible dc voltage
per conducting path has to be
considered.
For voltages higher than 250 volts,
the series connection of two or three
conducting paths is required.
As the current has to flow through
all conducting paths so as to maintain
the thermal tripping characteristics,
the following circuit arrangements are
recommended. With dc, the trip values
of the instantaneous short circuit
release (“n” release) are increased
by 30 to 40%.
Table 4. For 3- and 4-Pole Circuit Breakers
Proposed
Circuit
Maximum
Permissible
Vdc Ue
Remarks
250 Vdc Double-pole switching.
If there is no risk of an earth fault, or if any
earth fault which occurs is immediately elimi-
nated (earth fault monitoring), the maximum
permissible dc voltage can be 600 volts.
440 Vdc Double-pole switching (earth system).
The earthed pole must always be assigned to
the individual conducting path, so that two
paths are always in series in the event of an
earth fault.
600 Vdc Single-pole switching (earthed system).
Three conducting paths in series. The earthed
pole must be assigned to the nonswitched
conducting path.
750 Vdc Single-pole switching (earthed system).
Four conducting paths in series. The earthed
pole must be assigned to the nonswitched
conducting path.
NSI-5178a M
NSI-5179a M
NSI-5180 M
NSI-5181 M
July 2004
10
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Sizes JG through RG Vol. 1, Ref. No. [010]
Multi-Function Electronic
Trip Units for All Applications
Digitrip RMS Trip Units
True rms Sensing
Digitrip RMS Trip Units utilize our
patented microprocessor-based intelli-
gence to provide true rms sensing,
permitting increased accuracy and
reliable system protection. True rms
sensing is not susceptible to nuisance
tripping when waveforms containing
high harmonic currents are present.
Digitrip RMS 310
Digitrip RMS 310 Electronic Trip Units
are available with Cutler-Hammer
Circuit Breakers J-, L-, N- and R-
Frames 20 through 2500 amperes.
Digitrip RMS 310 Trip Units are avail-
able in four styles with either fixed
or adjustable rating plugs which
establishes the continuous ampere
rating of the breaker.
Note: JG- and LG-Frames have selectable
long time delay (tLD) and pickup settings
(Ir). A rating plug is not required.
Rating Plugs
If rating plugs are needed, they
are marked for 50/60 Hz applications.
Both fixed and adjustable rating
plugs are available, providing further
flexibility when applied to selectively
coordinated systems.
Note: Digitrip RMS rating plugs are
not interchangeable with SeltronicE
rating plugs.
Curve Shaping
When selectively coordinated systems
are called for, Digitrip RMS 310 will
provide a cost-effective solution for a
variety of applications.
The standard Digitrip RMS 310
includes an adjustable short time
pickup setting encompassing an I2t
ramp function which provides the
basic LS curve shaping function.
JG- and LG-Frames have an
adjustable long time delay.
Note: JG- and LG-Frames have selectable
long time delay (tLD) and pickup settings
(Ir). A rating plug is not required.
The optional Digitrip RMS 310
provides additional flat response
short time delay adjustments on
an instantaneous setting to provide
LSI curve shaping capability.
Digitrip RMS 310 Trip Units are
available with ground fault pickup
and flat response ground fault delay
which provides the trip unit with full
function LSG and LSIG curve shaping
flexibility.
Note: Contact factory for availability of
ground fault for LG-Frame trip unit.
Digitrip RMS 310 Trip Units can effec-
tively coordinate with both sophisti-
cated upstream power breakers as
well as downstream thermal magnetic
breakers…making Digitrip RMS 310
Trip Units the cost-effective reliable
choice for selectively coordinated
systems.
Thermal Memory
All Digitrip RMS Trip Units incorporate
a long delay. Thermal memory prevents
the system from cumulative overheating
due to repeated overcurrent events that
may occur in quick succession.
Field Testing
A field test kit is available for Digitrip
RMS 310 trip units.
Digitrip RMS 610 and 910
Digitrip RMS 610 and 910 Trip Units
are available with Cutler-Hammer
R-Frame Circuit Breakers 800 through
2500 amperes. Digitrip 610 and 910
Trip Units provide unparalleled
system protection with the added
convenience of a local display.
Curve Shaping
Digitrip RMS 610 and 910 Trip
Units are available with up to nine
curve shaping choices achieved by
adjusting up to seven switches on the
front of the unit for optimum system
coordination. Maximum curve shaping
flexibility is provided by dependent
long and short delay adjustments that
are long delay pickup (Ir) based,
depicted on the front of the unit by the
blue portion of the time-current curve.
Additional coordination capability
can be provided by utilizing the short
delay and ground fault zone selective
interlocking features available on
these trip units.
RMS 610 RMS 910
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
11
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size RG
Vol. 1, Ref. No. [011]
System Diagnostics
Digitrip RMS 610 and 910 models of
trip units provide long delay, short
delay, instantaneous, and ground fault
cause of trip LEDs on the front of the
unit. Their display shows a magnitude
of trip information, as well as remote
signal contacts, for improved system
alarming.
System Monitoring
Digitrip 610 and 910 Trip Units
have the capability to monitor
phase currents, as well as neutral or
ground currents. This information is
displayed on a large digital display
mounted on the unit.
Digitrip RMS 910 Trip Units can
also provide the user with power
and energy monitoring capability.
Peak power demand, present power
demand, and total energy, as well as
forward and reverse energy can be
monitored with this unit.
Digitrip RMS 910 Trip Units have the
additional capability of monitoring
line-to-line voltage, as well as system
power factor. Both parameters are dis-
played in the digital display window
and are supported by LEDs to indicate
which parameter is being displayed.
Harmonics Monitoring
Digitrip RMS 910 Trip Units are capa-
ble of displaying values of current
harmonics in the digital display win-
dow. Percentage of harmonic content
can be monitored for each phase,
up to the 27th harmonic. Additionally,
a total harmonic distortion value can
be calculated and displayed.
Communications
Digitrip RMS 910 units have built-in
communications options to allow all
protection, monitoring, and control
information to be transmitted back to a
central location via the Cutler-Hammer
PowerNetE system.
Field Testing
Integral field testing capability is
provided on all 610 and 910 Trip Units.
No additional test set is needed to per-
form both trip and no trip field testing.
July 2004
12
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Sizes JG through RG Vol. 1, Ref. No. [012]
Digitrip RMS Electronic Trip Unit Selection Guide
Table 5. Digitrip RMS Electronic Trip Unit Selection Guide
1JG- and LG-Frames have selectable settings
instead of a rating plug.
2JG- and LG-Frames have adjustable long
delay times of 2 – 24 seconds.
32500 ampere RG-Frame 200 – 600% x (In).
4JG-Frame also has a 14X setting.
5LS, LSG only.
6Not to exceed 1200 amperes.
7JG- and LG-Frames are Instantaneous, 120 ms.
NG- and RG-Frames are Instantaneous, 100,
300 and 500 ms.
Note: In= Rating plug rating.
Ir = Long delay setting.
Digitrip RMS 310 RMS 610 RMS 910
Breaker Type
Cutler-Hammer Frame(s) JG-, LG-, NG- and RG-Frames RG-Frame RG-Frame
Ampere Rating 20 – 2500 A 800 – 2500 A 800 – 2500 A
Interrupting Rating at 415 V 35, 70, 100 kA 70, 100 kA 70, 100 kA
Trip Unit Sensing
rms Sensing Yes Yes Yes
Protection and Coordination
Protection Ordering Options LS, LSG LSI, LSIG LI, LS, LSI, LIG, LSG, LSIG LI, LS, LSI, LIG, LSG, LSIG
Fixed Rating Plug (In) 1Yes Yes Yes Yes
Overtemperature Trip Yes Yes Yes Yes
Long Delay Adjustable Rating Plug (ln) 1Yes Yes No No
Long Delay Setting 0.5 – 1.0 (ln) 20.5 – 1.0 (ln) 20.5 – 1.0 x (ln) 0.5 – 1.0 x (ln)
Long Delay Time I2t at 6x 10 Seconds 210 Seconds 22 – 24 Seconds 2 – 24 Seconds
Long Delay Thermal Memory Yes Yes Yes Yes
High Load Alarm No No 0.85 x Ir0.85 x Ir
Short Delay Short Delay Setting 200 – 800% x (ln) 3200 – 800% x (ln) 3200 – 600% S1 & S2 x (Ir) 200 – 600% S1 & S2 x (Ir)
Short Delay Time I2t 100 ms No 100, 300, 500 ms 100, 300, 500 ms
Short Delay Time Flat No I – 300 ms 100 – 500 ms 100 – 500 ms
Short Delay Time ZSI No No Yes Yes
Instantaneous Instantaneous Setting No 200 – 800% x (ln) 4200 – 600% M1 & M2 x (ln) 200 – 600% M1 & M2 x (ln)
Discriminator No No Yes 5Yes 5
Instantaneous Override Yes Yes Yes Yes
Ground
Fault Ground Fault Setting Var/Frame 6Var/Frame 625 – 100% x (ln) 625 – 100% x (ln) 6
Ground Fault Delay I2t at .62x No No 100, 300, 500 ms 100, 300, 500 ms
Ground Fault Delay Flat I – 500 ms 7I – 500 ms 7100 – 500 ms 100 – 500 ms
Ground Fault ZSI No No Yes Yes
Ground Fault Thermal Memory No No Yes Yes
System Diagnostics
Cause of Trip LEDs No No Yes Yes
Magnitude of Trip Information No No Yes Yes
Remote Signal Contacts No No Yes Yes
System Monitoring
Digital Display No No Yes Yes
Current No No Yes Yes
Voltage No No No Yes
Power and Energy No No No Yes
Power Quality — Harmonics No No No Yes
Power Factor No No No Yes
System Communications
PowerNet No No No Yes
Field Testing
Testing Method Test Set Test Set Integral Integral
RG
JG
LG
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
13
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size EG, 160 Amperes (125 Amperes UL, CSA)
Vol. 1, Ref. No. [013]
EG-Frame, 160 Amperes — Selection Guide and Ordering Information
Table 6. Complete Circuit Breaker 1 — Includes Frame, Trip Unit, Standard Terminals and Metric Mounting Hardware
1Replace suffix “G” with “W” for no line and load terminals.
2Contact factory for availability of 2-pole breakers, and 0% neutral breakers prior to December 2004.
3Neutral protection is indicated by the fourth character: 4=0%, 7=100%.
416, 32, 63, 160 amperes are not UL or CSA listed ratings. Maximum UL or CSA rating for EG is 125 amperes. Adjustable thermal trip units are typically
used in IEC markets and are not UL or CSA listed.
Maximum
Continuous
Ampere
Rating
at 40°C 4
1-Pole 2-Pole 23-Pole 14-Pole 23
Fixed Thermal
Fixed Magnetic 4Fixed Thermal
Fixed Magnetic 4Fixed Thermal
Fixed Magnetic Adjustable Thermal
Fixed Magnetic 4Thermal
Range Fixed Thermal
Fixed Magnetic Adjustable Thermal
Fixed Magnetic 4Thermal
Range
IC Rating: 25 kAIC at 240 Vac IC Rating: 18 kAIC at 415 and 480 Vac
15
16
20
25
30
32
35
40
45
50
60
63
70
80
90
100
125
160
EGB1015FFG
EGB1016FFG
EGB1020FFG
EGB1025FFG
EGB1030FFG
EGB1032FFG
EGB1035FFG
EGB1040FFG
EGB1045FFG
EGB1050FFG
EGB1060FFG
EGB1063FFG
EGB1070FFG
EGB1080FFG
EGB1090FFG
EGB1100FFG
EGB1125FFG
EGB2015FFG
EGB2016FFG
EGB2020FFG
EGB2025FFG
EGB2030FFG
EGB2032FFG
EGB2035FFG
EGB2040FFG
EGB2045FFG
EGB2050FFG
EGB2060FFG
EGB2063FFG
EGB2070FFG
EGB2080FFG
EGB2090FFG
EGB2100FFG
EGB2125FFG
EGB3015FFG
EGB3016FFG
EGB3020FFG
EGB3025FFG
EGB3030FFG
EGB3032FFG
EGB3035FFG
EGB3040FFG
EGB3045FFG
EGB3050FFG
EGB3060FFG
EGB3063FFG
EGB3070FFG
EGB3080FFG
EGB3090FFG
EGB3100FFG
EGB3125FFG
EGB3160FFG
EGB3020AFG
EGB3025AFG
EGB3032AFG
EGB3040AFG
EGB3050AFG
EGB3063AFG
EGB3080AFG
EGB3100AFG
EGB3125AFG
EGB3160AFG
16 – 20
20 – 25
25 – 32
32 – 40
40 – 50
50 – 63
63 – 80
80 – 100
100 – 125
125 – 160
EGB7015FFG
EGB7016FFG
EGB7020FFG
EGB7025FFG
EGB7030FFG
EGB7032FFG
EGB7035FFG
EGB7040FFG
EGB7045FFG
EGB7050FFG
EGB7060FFG
EGB7063FFG
EGB7070FFG
EGB7080FFG
EGB7090FFG
EGB7100FFG
EGB7125FFG
EGB7160FFG
EGB7020AFG
EGB7025AFG
EGB7032AFG
EGB7040AFG
EGB7050AFG
EGB7063AFG
EGB7080AFG
EGB7100AFG
EGB7125AFG
EGB7160AFG
16 – 20
20 – 25
25 – 32
32 – 40
40 – 50
50 – 63
63 – 80
80 – 100
100 – 125
125 – 160
IC Rating: 35 kAIC at 240 Vac IC Rating: 25 kAIC at 415 and 480 Vac
15
16
20
25
30
32
35
40
45
50
60
63
70
80
90
100
125
160
EGE2015FFG
EGE2016FFG
EGE2020FFG
EGE2025FFG
EGE2030FFG
EGE2032FFG
EGE2035FFG
EGE2040FFG
EGE2045FFG
EGE2050FFG
EGE2060FFG
EGE2063FFG
EGE2070FFG
EGE2080FFG
EGE2090FFG
EGE2100FFG
EGE2125FFG
EGE3015FFG
EGE3016FFG
EGE3020FFG
EGE3025FFG
EGE3030FFG
EGE3032FFG
EGE3035FFG
EGE3040FFG
EGE3045FFG
EGE3050FFG
EGE3060FFG
EGE3063FFG
EGE3070FFG
EGE3080FFG
EGE3090FFG
EGE3100FFG
EGE3125FFG
EGE3160FFG
EGE3020AFG
EGE3025AFG
EGE3032AFG
EGE3040AFG
EGE3050AFG
EGE3063AFG
EGE3080AFG
EGE3100AFG
EGE3125AFG
EGE3160AFG
16 – 20
20 – 25
25 – 32
32 – 40
40 – 50
50 – 63
63 – 80
80 – 100
100 – 125
125 – 160
EGE7015FFG
EGE7016FFG
EGE7020FFG
EGE7025FFG
EGE7030FFG
EGE7032FFG
EGE7035FFG
EGE7040FFG
EGE7045FFG
EGE7050FFG
EGE7060FFG
EGE7063FFG
EGE7070FFG
EGE7080FFG
EGE7090FFG
EGE7100FFG
EGE7125FFG
EGE7160FFG
EGE7020AFG
EGE7025AFG
EGE7032AFG
EGE7040AFG
EGE7050AFG
EGE7063AFG
EGE7080AFG
EGE7100AFG
EGE7125AFG
EGE7160AFG
16 – 20
20 – 25
25 – 32
32 – 40
40 – 50
50 – 63
63 – 80
80 – 100
100 – 125
125 – 160
July 2004
14
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size EG, 160 Amperes (125 Amperes UL, CSA) Vol. 1, Ref. No. [014]
Table 6. Complete Circuit Breaker 1 — Includes Frame, Trip Unit, Standard Terminals and Metric Mounting Hardware (Continued)
1Replace suffix “G” with “W” for no line and load terminals.
2Contact factory for availability of 2-pole breakers, and 0% neutral breakers prior to December 2004.
3Neutral protection is indicated by the fourth character: 4=0%, 7=100%.
416, 32, 63, 160 amperes are not UL or CSA listed ratings. Maximum UL or CSA rating for EG is 125 amperes. Adjustable thermal trip units are typically
used in IEC markets and are not UL or CSA listed.
Table 7. Molded Case Switches
516, 32, 63, 160 amperes are not UL or CSA
listed ratings. Maximum UL or CSA rating for
EG is 125 amperes. Adjustable thermal trip
units are typically used in IEC markets and
are not UL or CSA listed.
Maximum
Continuous
Ampere
Rating
at 40°C 4
1-Pole 2-Pole 23-Pole 14-Pole 23
Fixed Thermal
Fixed Magnetic 4Fixed Thermal
Fixed Magnetic 4Fixed Thermal
Fixed Magnetic 4Adjustable Thermal
Fixed Magnetic 4Thermal
Range Fixed Thermal
Fixed Magnetic 4Adjustable Thermal
Fixed Magnetic 4Thermal
Range
IC Rating: 85 kAIC at 240 Vac 2 IC Rating: 40 kAIC at 415 Vac, 35 kAIC at 480 Vac
15
16
20
25
30
32
35
40
45
50
60
63
70
80
90
100
125
EGS1015FFG
EGS1016FFG
EGS1020FFG
EGS1025FFG
EGS1030FFG
EGS1032FFG
EGS1035FFG
EGS1040FFG
EGS1045FFG
EGS1050FFG
EGS1060FFG
EGS1063FFG
EGS1070FFG
EGS1080FFG
EGS1090FFG
EGS1100FFG
EGS1125FFG
EGS2015FFG
EGS2016FFG
EGS2020FFG
EGS2025FFG
EGS2030FFG
EGS2032FFG
EGS2035FFG
EGS2040FFG
EGS2045FFG
EGS2050FFG
EGS2060FFG
EGS2063FFG
EGS2070FFG
EGS2080FFG
EGS2090FFG
EGS2100FFG
EGS2125FFG
EGS3015FFG
EGS3016FFG
EGS3020FFG
EGS3025FFG
EGS3030FFG
EGS3032FFG
EGS3035FFG
EGS3040FFG
EGS3045FFG
EGS3050FFG
EGS3060FFG
EGS3063FFG
EGS3070FFG
EGS3080FFG
EGS3090FFG
EGS3100FFG
EGS3125FFG
EGS3020AFG
EGS3025AFG
EGS3032AFG
EGS3040AFG
EGS3050AFG
EGS3063AFG
EGS3080AFG
EGS3100AFG
EGS3125AFG
16 – 20
20 – 25
25 – 32
32 – 40
40 – 50
50 – 63
63 – 80
80 – 100
100 – 125
EGS7015FFG
EGS7016FFG
EGS7020FFG
EGS7025FFG
EGS7030FFG
EGS7032FFG
EGS7035FFG
EGS7040FFG
EGS7045FFG
EGS7050FFG
EGS7060FFG
EGS7063FFG
EGS7070FFG
EGS7080FFG
EGS7090FFG
EGS7100FFG
EGS7125FFG
EGS7020AFG
EGS7025AFG
EGS7032AFG
EGS7040AFG
EGS7050AFG
EGS7063AFG
EGS7080AFG
EGS7100AFG
EGS7125AFG
16 – 20
20 – 25
25 – 32
32 – 40
40 – 50
50 – 63
63 – 80
80 – 100
100 – 125
IC Rating: 100 kAIC at 240 Vac 2 IC Rating: 70 kAIC at 415 Vac, 65 kAIC at 480 Vac
15
16
20
25
30
32
35
40
45
50
60
63
70
80
90
100
125
EGH1015FFG
EGH1016FFG
EGH1020FFG
EGH1025FFG
EGH1030FFG
EGH1032FFG
EGH1035FFG
EGH1040FFG
EGH1045FFG
EGH1050FFG
EGH1060FFG
EGH1063FFG
EGH1070FFG
EGH1080FFG
EGH1090FFG
EGH1100FFG
EGH1125FFG
EGH2015FFG
EGH2016FFG
EGH2020FFG
EGH2025FFG
EGH2030FFG
EGH2032FFG
EGH2035FFG
EGH2040FFG
EGH2045FFG
EGH2050FFG
EGH2060FFG
EGH2063FFG
EGH2070FFG
EGH2080FFG
EGH2090FFG
EGH2100FFG
EGH2125FFG
EGH3015FFG
EGH3016FFG
EGH3020FFG
EGH3025FFG
EGH3030FFG
EGH3032FFG
EGH3035FFG
EGH3040FFG
EGH3045FFG
EGH3050FFG
EGH3060FFG
EGH3063FFG
EGH3070FFG
EGH3080FFG
EGH3090FFG
EGH3100FFG
EGH3125FFG
EGH3020AFG
EGH3025AFG
EGH3032AFG
EGH3040AFG
EGH3050AFG
EGH3063AFG
EGH3080AFG
EGH3100AFG
EGH3125AFG
16 – 20
20 – 25
25 – 32
32 – 40
40 – 50
–—
50 – 63
63 – 80
80 – 100
100 – 125
EGH7015FFG
EGH7016FFG
EGH7020FFG
EGH7025FFG
EGH7030FFG
EGH7032FFG
EGH7035FFG
EGH7040FFG
EGH7045FFG
EGH7050FFG
EGH7060FFG
EGH7063FFG
EGH7070FFG
EGH7080FFG
EGH7090FFG
EGH7100FFG
EGH7125FFG
EGH7020AFG
EGH7025AFG
EGH7032AFG
EGH7040AFG
EGH7050AFG
EGH7063AFG
EGH7080AFG
EGH7100AFG
EGH7125AFG
16 – 20
20 – 25
25 – 32
32 – 40
40 – 50
50 – 63
63 – 80
80 – 100
100 – 125
Ampere
Rating Number
of Poles Catalog
Number
125
160 3
3EGK3125KSG
EGK3160KSG 5
PG01200002E For more information visit: www.EatonElectrical.com
15
Series G Molded Case Circuit Breakers
July 2004 15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size EG, 160 Amperes (125 Amperes UL, CSA)
Vol. 1, Ref. No. [015]
Line and Load Terminals
EG-Frame circuit breakers and molded case switches have 3T125EF line and load
terminals as standard equipment.
Table 8. Line and Load Terminals
1Standard line and load terminals included with EG-Frame MCCBs.
23 terminals with terminal shield.
34 terminals with terminal shield.
Figure 3. Line and Load Terminals, and End Cap Kits
Insert collar enclosing conductor as
shown in Figure 3. Locate nut on top of
conductor and tighten securely with
screw and washer.
Caution: Collar must surround conductor.
Insert collar enclosing conductor and
center on extrusion. Tighten securely
with screw and washer.
End cap kits are used on the E-Frame
breaker line side to connect bus bar
or similar electrical connections.
Includes hardware.
Maximum Breaker
Amperes Terminal Body
Material Wire
Type Metric Wire
Range mm2AWG Wire
Range Catalog Number
Package of 3 Terminals
Standard Cu/Al Pressure Type Terminals
125 Steel Cu/Al 2.5-95 #14-3/0 3T125EF 1
125
125 Aluminum
Aluminum Cu/Al
Cu/Al 2.5-50
16-95 #14-1/0
#6-3/0 3TA125EF
3TA150EF
160
160 Aluminum
Aluminum Cu/Al
Cu/Al 35-120
35-120 #3-250
#3-250 3TA160EFK 2
4TA160EFK 3
3T125EF
3TA125EF 3TA150EF
3TA160EFK End Cap Kits
EF3RTWK, 3-Pole – Metric (for 3-pole line or load)
EF4RTWK, 4-Pole – Metric (for 4-pole line or load)
EF3RTDK, 3-Pole – Imperial (for 3-pole line or load)
EF4RTDK, 4-Pole – Imperial (for 4-pole line or load)
Control Wire Terminal Kit
For use with steel or stainless
steel terminals only.
Note: Standard line and load terminals
included with EG-Frame MCCBs.
Figure 4. Control Wire Terminal Kit
Table 9. Control Wire Terminal Kit
Interphase Barriers
The interphase barrier is available
for extended insulation between
circuit breaker poles. Specify quantity
when ordering.
Table 10. Interphase Barriers
Base Mounting Hardware
Metric base mounting hardware is
included with a circuit breaker or
molded case switch. A DIN rail adapter
is available.
Note: English mounting hardware kit can be
supplied: Catalog Number BMHE.
Table 11. Base Mounting Hardware
Description Catalog Number
Package of 12
(Priced Individually) GCWTK
Description Catalog Number
Package of 2 EIPBK
DIN Rail Adapter Catalog Number
3- or 4-Pole EF34DIN
July 2004
16
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size EG, 160 Amperes (125 Amperes UL, CSA) Vol. 1, Ref. No. [016]
Multiwire Connectors
Field-installed multiwire connectors
for the load side (OFF) end terminals.
They are used to distribute the load
from the circuit breaker to multiple
devices without the use of separate
distribution terminal blocks.
Multiwire lug kits include mounting
hardware, insulators and tin-plated
aluminum connectors to replace three
mechanical load lugs. UL listed for
copper only as used on the load side
(OFF) end.
Table 12. EG-Frame Multiwire Connectors
Ordering Information (Package of 3)
Figure 5. Multiwire Connectors
Terminal Shields
The terminal shield is available
for line terminal areas in 2-, 3- and
4-pole circuit breakers. The standard
style number by pole for each terminal
shield is for a package of 10 and is
priced per each package.
Table 13. Terminal Shields
Terminal End Covers (Gas Barrier)
The terminal end cover is available
for 3-pole circuit breakers only. Two
conductor opening sizes are available.
Specify quantity (one per circuit
breaker) when ordering.
Table 14. Terminal End Covers (Gas Barrier)
Maximum
Amperes Wires
per
Terminal
Wire Size
Range
AWG Cu
Kit
Catalog
Number
125
125 3
614 – 2
14 – 6 3TA100E3K
3TA100E6K
Number
of Poles Standard
Package of 10 IP30
Protection
2
3
4
EFTS2K
EFTS3K
EFTS4K
Conductor Opening
Diameter — Inches (mm) Catalog
Number
0.25 (6.4)
0.41 (10.4) EEC3K
EEC4K
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
17
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size JG, 250 Amperes
Vol. 1, Ref. No. [017]
JG-Frame, 250 Amperes — Selection Guide and Ordering Information
Table 15. Complete Circuit Breaker with Thermal-Magnetic Trip Unit —
Includes Frame, Thermal-Magnetic Trip Units Standard Terminals and Metric Mounting Hardware 1
1Replace suffix “G” with “W” for no line and load terminals.
2Contact factory for availability prior to December 2004.
3Neutral protection is indicated by the fourth character: 4 = 0%, 8 = adjustable 0 or 60% and 9 = 0 or 100%.
4Adjustable thermal trip units are typically used in IEC markets and are not UL or CSA listed.
Maximum
Continuous
Ampere
Rating
at 40°C
Magnetic
Range 2-Pole 23-Pole 4-Pole 3
Fixed
Thermal
Adjustable
Magnetic
Fixed
Thermal
Adjustable
Magnetic
Adjustable
Thermal
Adjustable
Magnetic 4
Thermal
Range Fixed
Thermal
Adjustable
Magnetic
Adjustable
Thermal
Adjustable
Magnetic 4
Thermal
Range
IC Rating: 25 kAIC at 415 and 480 Vac
70
80
90
100
125
150
160
175
200
225
250
350 – 700
400 – 800
450 – 900
500 – 1000
625 – 1250
750 – 1500
800 – 1600
875 – 1750
1000 – 2000
1125 – 2250
1250 – 2500
JGE2070FAG
JGE2080FAG
JGE2100FAG
JGE2125FAG
JGE2150FAG
JGE2175FAG
JGE2200FAG
JGE2225FAG
JGE2250FAG
JGE3070FAG
JGE3080FAG
JGE3100FAG
JGE3125FAG
JGE3150FAG
JGE3175FAG
JGE3200FAG
JGE3225FAG
JGE3250FAG
JGE3080AAG
JGE3100AAG
JGE3125AAG
JGE3160AAG
JGE3200AAG
JGE3250AAG
64 – 80
80 – 100
100 – 125
128 – 160
160 – 200
200 – 250
JGE4070FAG
JGE4080FAG
JGE4100FAG
JGE4125FAG
JGE4150FAG
JGE4175FAG
JGE4200FAG
JGE4225FAG
JGE4250FAG
JGE4080AAG
JGE4100AAG
JGE4125AAG
JGE4160AAG
JGE4200AAG
JGE4250AAG
80 – 100
100 – 125
128 – 160
160 – 200
200 – 250
IC Rating: 40 kAIC at 415 Vac, 35 kAIC at 480 Vac
70
80
90
100
125
150
160
175
200
225
250
350 – 700
400 – 800
450 – 900
500 – 1000
625 – 1250
750 – 1500
800 – 1600
875 – 750
1000 – 2000
1125 – 2250
1250 – 2500
JGS2070FAG
JGS2090FAG
JGS2100FAG
JGS2125FAG
JGS2150FAG
JGS2175FAG
JGS2200FAG
JGS2225FAG
JGS2250FAG
JGS3070FAG
JGS3090FAG
JGS3100FAG
JGS3125FAG
JGS3150FAG
JGS3175FAG
JGS3200FAG
JGS3225FAG
JGS3250FAG
JGS3080AAG
JGS3100AAG
JGS3125AAG
JGS3160AAG
JGS3200AAG
JGS3250AAG
64 – 80
64 – 80
80 – 100
100 – 125
128 – 160
160 – 200
200 – 250
JGS4070FAG
JGS4090FAG
JGS4100FAG
JGS4125FAG
JGS4150FAG
JGS4175FAG
JGS4200FAG
JGS4225FAG
JGS4250FAG
JGS4080AAG
JGS4100AAG
JGS4125AAG
JGS4160AAG
JGS4200AAG
JGS4250AAG
80 – 100
100 – 125
128 – 160
160 – 200
200 – 250
IC Rating: 70 kAIC at 415 Vac, 65 kAIC at 480 Vac
70
80
90
100
125
150
160
175
200
225
250
350 – 700
400 – 800
450 – 900
500 – 1000
625 – 1250
750 – 1500
800 – 1600
875 – 1750
1000 – 2000
1125 – 2250
1250 – 2500
JGH2070FAG
JGH2090FAG
JGH2100FAG
JGH2125FAG
JGH2150FAG
JGH2175FAG
JGH2200FAG
JGH2225FAG
JGH2250FAG
JGH3070FAG
JGH3090FAG
JGH3100FAG
JGH3125FAG
JGH3150FAG
JGH3175FAG
JGH3200FAG
JGH3225FAG
JGH3250FAG
JGH3080AAG
JGH3100AAG
JGH3125AAG
JGH3160AAG
JGH3200AAG
JGH3250AAG
64 – 80
64 – 80
80 – 100
100 – 125
128 – 160
160 – 200
200 – 250
JGH4070FAG
JGH4090FAG
JGH4100FAG
JGH4125FAG
JGH4150FAG
JGH4160FAG 4
JGH4175FAG
JGH4200FAG
JGH4225FAG
JGH4250FAG
JGH4080AAG
JGH4100AAG
JGH4125AAG
JGH4160AAG
JGH4200AAG
JGH4250AAG
80 – 100
100 – 125
128 – 160
160 – 200
200 – 250
IC Rating: Component Frame Only — 25 kAIC at 415 and 480 Vac
250 JGE2250NN JGE3250NN JGE4250NN
IC Rating: Component Frame Only — 40 kAIC at 415 Vac, 35 kAIC at 480 Vac
250 JGS2250NN JGS3250NN JGS4250NN
IC Rating: Component Frame Only — 70 kAIC at 415 Vac, 65 kAIC at 480 Vac
250 JGH2250NN JGH3250NN JGH4250NN
Thermal-Magnetic Trip Unit
70
80
90
100
125
150
160
175
200
225
250
350 – 700
400 – 800
450 – 900
500 – 1000
625 – 1250
750 – 1500
800 – 1600
875 – 1750
1000 – 2000
1125 – 2250
1250 – 2500
JT2070FA
JT2090FA
JT2100FA
JT2125FA
JT2150FA
JT2160FA 4
JT2175FA
JT2200FA
JT2225FA
J2T250FA
JT3070FA
JT3090FA
JT3100FA
JT3125FA
JT3150FA
JT3175FA
JT3200FA
JT3225FA
JT3250FA
JT3080AA 4
JT3100AA 4
JT3125AA 4
JT3160AA 4
JT3200AA 4
JT3250AA 4
64 – 100
80 – 100
100 – 125
128 – 160
160 – 200
200 – 250
JT4070FA
JT4090FA
JT4100FA
JT4125FA
JT4150FA
JT4175FA
JT4200FA
JT4225FA
JT4250FA
JT4080AA 4
JT4100AA 4
JT4125AA 4
JT4160AA 4
JT4200AA 4
JT4250AA 4
80 – 100
100 – 125
128 – 160
160 – 200
200 – 250
July 2004
18
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size JG, 250 Amperes Vol. 1, Ref. No. [018]
Table 16. Complete JG Breakers with Electronic Trip Unit 12
1Replace suffix “G” with “W” for no line and load terminals.
2For ac use only.
3Neutral CT for LSG and LSIG applied to 4-wire applications must be ordered as a separate item.
4Required for 4-wire systems if neutral protection is desired.
5For 2-pole applications, use two outer poles.
6Neutral protection 4 = 0%, 6 = 60%, 7 = 100% electronic trip unit neutral protection is not
adjustable.
Ampere
Rating LS LSI LSG 3LSIG 3Neutral CT 34
for LSG & LSIG
3-Pole 5 — IC Rating: 25 kAIC at 415 and 480 Vac
50
100
160
250
JGE305033G
JGE310033G
JGE316033G
JGE325033G
JGE305032G
JGE310032G
JGE316032G
JGE325032G
JGE305035G
JGE310035G
JGE316035G
JGE325035G
JGE305036G
JGE310036G
JGE316036G
JGE325036G
JGFCT050
JGFCT100
JGFCT160
JGFCT250
4-Pole 6 — IC Rating: 25 kAIC at 415 and 480 Vac
50
100
160
250
JGE405033G
JGE410033G
JGE416033G
JGE425033G
JGE405032G
JGE410032G
JGE416032G
JGE425032G
JGE405035G
JGE410035G
JGE416035G
JGE425035G
JGE405036G
JGE410036G
JGE416036G
JGE425036G
JGFCT050
JGFCT100
JGFCT160
JGFCT250
3-Pole — IC Rating: 40 kAIC at 415 Vac, 35 kAIC at 480 Vac
50
100
160
250
JGS305033G
JGS310033G
JGS316033G
JGS325033G
JGS305032G
JGS310032G
JGS316032G
JGS325032G
JGS305035G
JGS310035G
JGS316035G
JGS325035G
JGS305036G
JGS310036G
JGS316036G
JGS325036G
JGFCT050
JGFCT100
JGFCT160
JGFCT250
4-Pole 6 — IC Rating: 40 kAIC at 415 Vac, 35 kAIC at 480 Vac
50
100
160
250
JGS405033G
JGS410033G
JGS416033G
JGS425033G
JGS405032G
JGS410032G
JGS416032G
JGS425032G
JGS405035G
JGS410035G
JGS416035G
JGS425035G
JGS405036G
JGS410036G
JGS416036G
JGS425036G
JGFCT050
JGFCT100
JGFCT160
JGFCT250
3-Pole — IC Rating: 70 kAIC at 415 Vac, 65 kAIC at 480 Vac
50
100
160
250
JGH305033G
JGH310033G
JGH316033G
JGH325033G
JGH305032G
JGH310032G
JGH316032G
JGH325032G
JGH305035G
JGH310035G
JGH316035G
JGH325035G
JGH305036G
JGH310036G
JGH316036G
JGH325036G
JGFCT050
JGFCT100
JGFCT160
JGFCT250
4-Pole 6 — IC Rating: 70 kAIC at 415 Vac, 65 kAIC at 480 Vac
50
100
160
250
JGH405033G
JGH410033G
JGH416033G
JGH425033G
JGH405032G
JGH410032G
JGH416032G
JGH425032G
JGH405035G
JGH410035G
JGH416035G
JGH425035G
JGH405036G
JGH410036G
JGH416036G
JGH425036G
JGFCT050
JGFCT100
JGFCT160
JGFCT250
PG01200002E For more information visit: www.EatonElectrical.com
19
Series G Molded Case Circuit Breakers
July 2004 15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size JG, 250 Amperes
Vol. 1, Ref. No. [019]
Table 17. JG Electronic Trip Units
1Required for 4-wire systems if neutral protection is desired.
2Neutral protection 4 = 0%, 6 = 60%, 7 = 100% electronic trip unit neutral protection is not
adjustable.
Note: Long time pickup no rating plug.
250 Ampere Settings 250, 225, 200, 175, 160, 150, 125, 100.
160 Ampere Settings 160, 150, 125, 110, 100, 90, 80, 63.
100 Ampere Settings 100, 90, 80, 70, 63, 50, 45, 40.
50 Ampere Settings 50, 45, 40, 32, 30, 25, 20.
Note: Adjustable long time delay — 2 – 24 seconds at 6 x Ir.
Adjustable short time delay — Inst., 120, 300 ms.
Note: Plug-in test kit — Catalog Numbers MTST120V (120 Vac) or MTST230V (230 Vac).
Digitrip 310+ Test Kit
Digitrip 310+ Test Kit Shown with JG MCCB
JG Digitrip 310+ Electronic Trip Unit
Ampere
Rating LS LSI LSG LSIG Neutral CT 1
for LSG & LSIG
3-Pole
50
100
160
250
JT305033
JT310033
JT316033
JT325033
JT305032
JT310032
JT316032
JT325032
JT305035
JT310035
JT316035
JT325035
JT305036
JT310036
JT316036
JT325036
JGFCT050
JGFCT100
JGFCT160
JGFCT250
4-Pole 2
50
100
160
250
JT405033
JT410033
JT416033
JT425033
JT405032
JT410032
JT416032
JT425032
JT405035
JT410035
JT416035
JT425035
JT405036
JT410036
JT416036
JT425036
JGFCT050
JGFCT100
JGFCT160
JGFCT250
Table 18. Molded Case Switches 3
(Includes Line and Load Collars)
3For 2-pole applications, use outer poles
of a 3-pole MCS.
4100% neutral protection.
Ampere
Rating Number
of Poles Catalog
Number
250 3
4JGK3250KSG
JGK7250KSG 4
July 2004
20
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size JG, 250 Amperes Vol. 1, Ref. No. [020]
Line and Load Terminals
JG-Frame circuit breakers include Cu/Al terminals T250FJ as standard.
When optional copper only terminals are required, order by catalog number.
Table 19. Line and Load Terminals
1Single terminals individually packed.
2Standard line and load terminals.
3Contact factory for availability.
Figure 6. Standard Pressure Type Terminal
T250FJ
Figure 7. Standard and Optional Pressure
Type Terminal TA250FJ/TC250FJ
End Cap Kit
End cap kits are used on J250-Frame
breaker line side to connect bus bar
or similar electrical connections.
Includes hardware.
Table 20. Kit Catalog Number —
for Line or Load
Control Wire Terminal Kit
For use with aluminum or copper
terminals only.
Table 21. Control Wire Terminal Kit
Maximum
Breaker
Amperes
Terminal
Body
Material
Wire
Type Metric Wire
Range mm2AWG Wire
Range/Number
of Conductors
Catalog
Number
Standard Pressure Type Terminals
250
250 Stainless Steel
Aluminum Cu
Cu/Al 25 – 185
25 – 185 #4 – 350 (1)
#4 – 350 (1) T250FJ 12
TA250FJ 1
Optional Copper and Cu/Al Pressure Type Terminals
250 Copper Cu/Al 25 – 185 #4 – 350 (1) TC250FJ 13
Number
of Poles Catalog Number
Metric Imperial
3
4FJ3RTWK
FJ4RTWK FJ3RTDK
FJ4RTDK
Description Catalog Number
Package of 14
(Priced Individually) FJCWTK
Multiwire Connectors
Field-installed multiwire connectors
for the load side (OFF) end terminals.
They are used to distribute the load
from the circuit breaker to multiple
devices without the use of separate
distribution terminal blocks.
Multiwire lug kits include mounting
hardware, insulators and tin-plated
aluminum connectors to replace three
mechanical load lugs. UL listed for
copper only as used on the load side
(OFF) end.
Table 22. JG-Frame Multiwire Connectors
Ordering Information (Package of 3)
Figure 8. JG-Frame Multiwire Connectors
Base Mounting Hardware
Base mounting hardware is included
with a circuit breaker or molded
case switch.
Table 23. Terminal Shields IP30
Table 24. Interphase Barriers
Maximum
Amperes Wires
per
Terminal
Wire Size
Range
AWG Cu
Kit
Catalog
Number
250
250 3
614 – 2
14 – 6 3TA250J3
3TA250J6
Location Number of
Poles Catalog Number
Package of 10
Line or Load 2, 3
4FJTS3K
FJTS4K
Package of 2
Number of Poles Catalog Number
3
4FJIPBK
FJIPBK4
PG01200002E For more information visit: www.EatonElectrical.com
21
Series G Molded Case Circuit Breakers
July 2004 15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size LG, 630 Amperes (600 Amperes UL, CSA)
Vol. 1, Ref. No. [021]
LG-Frame, 630 Amperes
Table 26. Thermal Magnetic Trip Unit
7For 2-pole applications, use two outer poles.
8Neutral protection is indicated by the third character: 4 = 0%, 7 = 100%, 8 = adjustable 0 – 60% and
9 = 0 – 100%
9Adjustable thermal, adjustable magnetic trip units are typically used in IEC markets and are
not UL or CSA listed.
Table 25. Complete Breaker (Includes Frame, Trip Unit, Standard Terminals and Mounting Hardware) 1
Ampere
Rating 3-Pole 24-Pole (0%) 33-Pole 24-Pole (0%) 3
Fixed Thermal
Adj. Magnetic Adj. Thermal
Adj. Magnetic 45 Fixed Thermal
Adj. Magnetic Adj. Thermal
Adj. Magnetic 45 Fixed Thermal
Adj. Magnetic Adj. Thermal
Adj. Magnetic 45 Fixed Thermal
Adj. Magnetic Adj. Thermal
Adj. Magnetic 45
IC Rating: 35 kAIC at 415 and 480 Vac IC Rating: 50 kAIC at 415 and 480 Vac
250
300
320
350
LGE3250FAG
LGE3300FAG
LGE3350FAG
LGE3250AAG
LGE3320AAG
LGE4250FAG
LGE4300FAG
LGE4350FAG
LGE4250AAG
LGE4320AAG
LGS3250FAG
LGS3300FAG
LGS3350FAG
LGS3250AAG
LGS3320AAG
LGS4250FAG
LGS4350FAG
LGS4350FAG
LGS4250AAG
LGS4320AAG
400
500
600
630 4
LGE3400FAG
LGE3500FAG
LGE3600FAG
LGE3400AAG
LGE3500AAG
LGE3630AAG
LGE4400FAG
LGE4500FAG
LGE4600FAG
LGE4400AAG
LGE4500AAG
LGE4630AAG
LGS3400FAG
LGS3500FAG
LGS3600FAG
LGS3400AAG
LGS3500AAG
LGS3630AAG
LGS4400FAG
LGS4500FAG
LGS4600FAG
LGS4400AAG
LGS4500AAG
LGS4630AAG
IC Rating: 70 kAIC at 415 Vac, 65 kAIC at 480 Vac IC Rating: 100 kAIC at 415 and 480 Vac 6
250
300
320
350
LGH3250FAG
LGH3300FAG
LGH3350FAG
LGH3250AAG
LGH3320AAG
LGH4250FAG
LGH4300FAG
LGH4350FAG
LGH4250AAG
LGH4320AAG
LGC3250FAG
LGC3300FAG
LGC3350FAG
LGC3250AAG
LGC3320AAG
LGC4250FAG
LGC4300FAG
LGC4350FAG
LGC4250AAG
LGC4320AAG
400
500
600
630 4
LGH3400FAG
LGH3500FAG
LGH3600FAG
LGH3400AAG
LGH3500AAG
LGH3630AAG
LGH4400FAG
LGH4500FAG
LGH4600FAG
LGH4400AAG
LGH4500AAG
LGH4630AAG
LGC3400FAG
LGC3500FAG
LGC3600FAG
LGC3400AAG
LGC3500AAG
LGC3630AAG
LGC4400FAG
LGC4500FAG
LGC4600FAG
LGC4400AAG
LGC4500AAG
LGC4630AAG
1Replace suffix “G” with “W” for no line and load terminals.
2For 2-pole applications, use two outer poles.
3Neutral protection is indicated by the fourth character: 4 = 0%, 7 = 100%, 8 = adjustable 0 – 60% and 9 = 0 – 100%.
4630 amperes is not a UL or CSA listed rating. 600 amperes is the maximum UL and CSA rating for the LG.
5Adjustable thermal units are typically used in IEC markets and are not UL or CSA listed.
6Contact factory if needed before December 2004.
Ampere
Rating 3-Pole 74-Pole (0%) 8
Fixed Thermal/
Adj. Magnetic Adj. Thermal/
Adj. Magnetic 9Fixed Thermal/
Adj. Magnetic Adj. Thermal/
Adj. Magnetic 9
250
300
320
350
LT3250FA
LT3300FA
LT3350FA
LT3250AA
LT3320AA
LT4250FA
LT4300FA
LT4350FA
LT4250AA
LT4320AA
400
500
600
630
LT3400FA
LT3500FA
LT3600FA
LT3400AA
LT3500AA
LT3630AA
LT4400FA
LT4500FA
LT4600FA
LT4400AA
LT4500AA
LT4630AA
Table 27. Molded Case Switches
jFor 2-pole applications, use two outer poles.
k630 amperes is not a UL or CSA listed
rating. 600 amperes is the maximum UL and
CSA rating for the LG.
Table 28. Components Frame
l630 amperes is not a UL or CSA listed
rating. 600 amperes is the maximum UL and
CSA rating for the LG.
mFor 2-pole applications, use two outer poles.
nContact factory if needed before
December 2004.
Ampere
Rating Number
of Poles Catalog
Number
400 3 j
4LGK3400KSG
LGK4400KSG
630 k3 j
4LGK3630KSG
LGK4630KSG
Ampere
Rating
l
IC Rating
at 415/
480 V
3-Pole m4-Pole
(0%)
630
630
630
630
35/35
50/50
70/65
100/100 n
LGE3630NN
LGS3630NN
LGH3630NN
LGC3630NN
LGE4630NN
LGS4630NN
LGH4630NN
LGC4630NN
July 2004
22
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size LG, 630 Amperes (600 Amperes UL, CSA) Vol. 1, Ref. No. [022]
Table 29. Electronic Trip Units — Digitrip 310+
1Required for 4-wire systems if neutral protection is desired.
2630 amperes is not a UL or CSA listed rating. 600 amperes is the maximum UL and CSA listed
rating for the LG.
3Neutral protection: 4= 0%, 6 = 60%, 7 = 100%. Electronic trip unit neutral protection is not
adjustable.
Note: Long time pickup no rating plug needed.
630 Ampere Settings 630, 600, 500, 400, 350, 315, 300, 250 (315, 630 are IEC ratings only).
600 Ampere Settings 600, 500, 450, 400, 350, 315, 300, 250 (315 is IEC rating only).
400 Ampere Settings 400, 350, 315, 300, 250, 225, 200, 160 (315 is IEC rating only).
250 Ampere Settings 250, 225, 200, 175, 160, 150, 125, 100 (160 is IEC rating only).
Note: Adjustable long time delay — 2 – 24 seconds at 6 x Ir.
Adjustable short time delay — Inst., 120, 300 ms.
Note: Plug-in test kit — Catalog Numbers MTST120V (120 Vac) and MTST230V (230 Vac).
Ampere
Rating LS LSI LSG LSIG Neutral CT
for LSG & LSIG 1
3-Pole
250
400
600
630 2
LT325033
LT340033
LT360033
LT363033
LT325032
LT340032
LT360032
LT363032
LT325035
LT340035
LT360035
LT363035
LT325036
LT340036
LT360036
LT363036
LGFCT250
LGFCT400
LGFCT600
LGFCT630
4-Pole 3
250
400
600
630 2
LT425033
LT440033
LT460033
LT463033
LT425032
LT440032
LT460032
LT463032
LT425035
LT440035
LT460035
LT463035
LT425036
LT440036
LT460036
LT463036
LGFCT250
LGFCT400
LGFCT600
LGFCT630
Digitrip 310+ Test Kit
Digitrip 310+ Test Kit Shown with JG MCCB
LG Digitrip 310+ Electronic Trip Unit
PG01200002E For more information visit: www.EatonElectrical.com
23
Series G Molded Case Circuit Breakers
July 2004 15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size LG, 630 Amperes (600 Amperes UL, CSA)
Vol. 1, Ref. No. [023]
Table 30. IC Rating at 415/480 V — Complete LG Breakers with Electronic Trip Unit
(Includes Frame, Trip Unit, Standard Terminals and Mounting Hardware) 1
1Replace suffix “G” with “W” for no line and load terminals.
2Required for 4-wire systems if neutral protection is desired.
3For 2-pole applications, use two outer poles.
4630 amperes is not a UL or CSA listed rating. 600 amperes is the maximum UL and CSA listed
rating for the LG.
5Neutral protection: 4= 0%, 6 = 60%, 7 = 100%. Electronic trip unit neutral protection is not
adjustable.
Ampere
Rating LS LSI LSG LSIG Neutral CT
for LSG & LSIG 2
3-Pole 3 — IC Rating: 35 kAIC at 415 and 480 Vac
250
400
600
630 4
LGE325033G
LGE340033G
LGE360033G
LGE363033G
LGE325032G
LGE340032G
LGE360032G
LGE363032G
LGE325035G
LGE340035G
LGE360035G
LGE363035G
LGE325036G
LGE340036G
LGE360036G
LGE363036G
LGFCT250
LGFCT400
LGFCT600
LGFCT630
4-Pole 5 — IC Rating: 35 kAIC at 415 and 480 Vac
250
400
600
630 4
LGE425033G
LGE440033G
LGE460033G
LGE463033G
LGE425032G
LGE440032G
LGE460032G
LGE463032G
LGE425035G
LGE440035G
LGE460035G
LGE463035G
LGE425036G
LGE440036G
LGE460036G
LGE463036G
LGFCT250
LGFCT400
LGFCT600
LGFCT630
3-Pole 3 — IC Rating: 50 kAIC at 415 and 480 Vac
250
400
600
630 4
LGS325033G
LGS340033G
LGS360033G
LGS363033G
LGS325032G
LGS340032G
LGS360032G
LGS363032G
LGS325035G
LGS340035G
LGS360035G
LGS363035G
LGS325036G
LGS340036G
LGS360036G
LGS363036G
LGFCT250
LGFCT400
LGFCT600
LGFCT630
4-Pole 5 — IC Rating: 50 kAIC at 415 and 480 Vac
250
400
600
630 4
LGS425033G
LGS440033G
LGS460033G
LGS463033G
LGS425032G
LGS440032G
LGS460032G
LGS463032G
LGS425035G
LGS440035G
LGS460035G
LGS463035G
LGS425036G
LGS440036G
LGS460036G
LGS463036G
LGFCT250
LGFCT400
LGFCT600
LGFCT630
3-Pole 3 — IC Rating: 70 kAIC at 415 Vac, 65 kAIC at 480 Vac
250
400
600
630 4
LGH325033G
LGH340033G
LGH360033G
LGH363033G
LGH325032G
LGH340032G
LGH360032G
LGH363032G
LGH325035G
LGH340035G
LGH360035G
LGH363035G
LGH325036G
LGH340036G
LGH360036G
LGH363036G
LGFCT250
LGFCT400
LGFCT600
LGFCT630
4-Pole 5 — IC Rating: 70 kAIC at 415 Vac, 65 kAIC at 480 Vac
250
400
600
630 4
LGH425033G
LGH440033G
LGH460033G
LGH463033G
LGH425032G
LGH440032G
LGH460032G
LGH463032G
LGH425035G
LGH440035G
LGH460035G
LGH463035G
LGH425036G
LGH440036G
LGH460036G
LGH463036G
LGFCT250
LGFCT400
LGFCT600
LGFCT630
July 2004
24
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size LG, 630 Amperes (600 Amperes UL, CSA) Vol. 1, Ref. No. [024]
Line and Load Terminals
Table 31. Line and Load Terminals
1Includes LTS3K (3-pole) or LTS4K (4-pole) terminal covers.
2Standard terminal included with complete breaker.
Table 32. Terminal Covers
3Included in TA63IL, T63IL, TA632L kits
listed above.
Table 33. End Cap Kits
Table 34. Terminal Extensions
Table 35. Terminal Spreaders
Figure 9. Terminals and Terminal Cover for the LG Breaker — Includes LTS3K (3-Pole) or LTS4K (4-Pole) Terminal Covers
Note: Extended terminal covers add 2.13 inches (54.0 mm) to breaker length.
Maximum Breaker
Amperes Terminal Body
Material Wire
Type AWG Wire Range/
Number of Conductors Metric Wire
Range (mm2)Number of
Terminals Included Catalog
Number
400
400 Aluminum
Aluminum Cu/Al
Cu/Al 500 – 750 (1)
500 – 750 (1) 240 – 380 (1)
240 – 380 (1) 3
43TA631LK 1
4TA631LK 1
400
400 Copper
Copper Cu
Cu 500 – 750 (1)
500 – 750 (1) 240 – 380 (1)
240 – 380 (1) 3
43T631LK 1
4T631LK 1
630
630 Aluminum
Aluminum Cu/Al
Cu/Al 2 – 500 (2)
2 – 500 (2) 35 – 240 (2)
35 – 240 (2) 3
43TA632LK 12
4TA632LK 12
630
630 Copper
Copper Cu
Cu 2 – 500 (2)
2 – 500 (2) 35 – 240 (2)
35 – 240 (2) 3
43T632LK 1
4T632LK 1
400
400 Aluminum
Copper Cu/Al
Cu 2 – 500 (1)
2 – 500 (1) 35 – 240 (1)
35 – 240 (1) 1
1TA350LK 2
T350LK
Description Catalog
Number
3-Pole Terminal Cover 3
4-Pole Terminal Cover 3LTS3K
LTS4K
Number
of Poles Catalog
Number
3
4L3RTWK
L4RTWK
Number
of Poles Catalog
Number
3
4LGTEW3
LGTEW4
Number
of Poles Catalog
Number
3
4LGTES3
LGTES4
Warning
Label
TA350L or
T350L Terminal TA631L, T631L, T632L
or TA632L step-type terminal kits
listed above include LTS3K (3-pole)
or LTS4K (4-pole) terminal
cover and warning label (required
for proper application).
Terminal Cover
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
25
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size NG, 1200 Amperes 50 kA at 480 Vac or 415 Vac
Vol. 1, Ref. No. [025]
NG-Frame, 1200 Amperes — Selection Guide and Ordering Information
Table 36. Type NGS Standard Interrupting Capacity — Ue Max. 690 Vac, 50 kA lcu at 480 Vac or 415 Vac
1For ac use only.
2NG MCCBs are suitable for 40°C or 50°C applications. Order suffix V3 to eliminate standard 40°C labeling.
3Order terminals separately.
4Unprotected left pole neutral. Insert “E” for 100% neutral or “EH” for 60% neutral between “W” and “P” (e.g., NGS412T32EHP08).
5Non-UL listed NG 1250 with 1250 ampere trip unit is also available.
Note: NG MCCBs have metric threading on line and load conductors. Use ND MCCBs if imperial threading is required.
Table 37. Molded Case Switches 67
6For ac use only.
7For 2-pole applications, use outer poles of 3-pole molded case switch.
Maximum
Continuous
Ampere
Rating
at 40°C 12
Number
of Poles Circuit Breaker Frame Including Digitrip RMS 310 Electronic Trip Unit with
Adjustable Rating Plugs — Catalog Number 3Interchangeable
Rating Plugs
(Order as Individual
Component)
Included
with Breaker
L Adjustable Long Delay Pickup (By Adjustable Rating Plug)
S Adjustable Short Delay Pickup with Fixed Short Delay Time
(I2t Response) or Adjustable Short Delay Time (Flat Response)
I Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous
G Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response)
LS LSI LSG LSIG Fixed Rating Plug Adj. Rating Plug
Short Time Range
Short Time Delay
Ground Fault Pickup
Ground Fault Delay
2 – 8 x In
2 – 8 x In
I – 300 ms
2 – 8 x In
200 – 1200 A
I – 500 ms
2 – 8 x In
I – 300 ms
200 – 1200 A
I – 500 ms
Ampere
Rating Catalog
Number Adjustable
Ampere
Settings
Catalog Number
800 2-Pole NGS2800T33WP18 NGS2800T32WP18 NGS2800T35WP18 NGS2800T36WP18 400
450
500
550
8NES400T
8NES450T
8NES500T
8NES550T
400/500/600/800
A8NES800T1
600
630
700
800
8NES600T
8NES630T
8NES700T
8NES800T
3-Pole NGS3800T33WP18 NGS3800T32WP18 NGS3800T35WP18 NGS3800T36WP18 400
450
500
550
8NES400T
8NES450T
8NES500T
8NES550T
400/500/600/800
A8NES800T1
600
630
700
800
8NES600T
8NES630T
8NES700T
8NES800T
4-Pole 4NGS4800T33WP18 NGS4800T32WP18 400
450
500
550
8NES400T
8NES450T
8NES500T
8NES550T
400/500/600/800
A8NES800T1
600
630
700
800
8NES600T
8NES630T
8NES700T
8NES800T
1200 52-Pole NGS212T33WP08 5NGS212T32WP08 5NGS212T35WP08 5NGS212T36WP08 5 600
630
700
800
12NES600T
12NES630T
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
12NES900T
12NES1000T
12NES1200T
3-Pole NGS312T33WP08 5NGS312T32WP08 5NGS312T35WP08 5NGS312T36WP08 5 600
630
700
800
12NES600T
12NES630T
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
12NES900T
12NES1000T
12NES1200T
4-Pole 4NGS412T33WP08 5NGS412T32WP08 5—— 600
630
700
800
12NES600T
12NES630T
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
12NES900T
12NES1000T
12NES1200T
Ampere Rating Number of Poles Ue Max. 690 Vac Catalog Number
800 3-Pole
4-Pole NGK3800KSW
NGK4800KSW MCS Only without
Line and Load Terminals
1250 3-Pole
4-Pole NGK312KSW
NGK412KSW MCS Only without
Line and Load Terminals
July 2004
26
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size NG, 1200 Amperes 65 kA at 480 Vac, 70 kA at 415 Vac Vol. 1, Ref. No. [026]
Table 38. Type NGH High Interrupting Capacity — Ue Max. 690 Vac, 65 kA Icu at 480 Vac, 70 kA Icu at 415 Vac
1For ac use only.
2NG MCCBs are suitable for 40°C or 50°C applications. Order suffix V3 to eliminate standard 40°C labeling.
3Order terminals separately.
4Unprotected left pole neutral. Insert “E” for 100% neutral or “EH” for 60% neutral between “W” and “P” (e.g., NGS412T32EHP08).
5Non-UL listed NG 1250 with 1250 ampere trip unit is also available.
Note: NG MCCBs have metric threading on line and load conductors. Use ND MCCBs if imperial threading is required.
Maximum
Continuous
Ampere
Rating
at 40°C 12
Number
of Poles Circuit Breaker Frame Including Digitrip RMS 310 Electronic Trip Unit with
Adjustable Rating Plugs — Catalog Number 3Interchangeable
Rating Plugs
(Order as Individual
Component)
Included
with Breaker
L Adjustable Long Delay Pickup (By Adjustable Rating Plug)
S Adjustable Short Delay Pickup with Fixed Short Delay Time
(I2t Response) or Adjustable Short Delay Time (Flat Response)
I Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous
G Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response)
LS LSI LSG LSIG Fixed
Rating Plug Adjustable
Rating Plug
Short Time Range
Short Time Delay
Ground Fault Pickup
Ground Fault Delay
2 – 8 x In
2 – 8 x In
I – 300 ms
2 – 8 x In
200 – 1200 A
I – 500 ms
2 – 8 x In
I – 300 ms
200 – 1200 A
I – 500 ms
Ampere
Rating Catalog
Number Adjustable
Ampere
Settings
Catalog Number
800 2-Pole NGH2800T33WP18 NGH2800T32WP18 NGH2800T35WP18 NGH2800T36WP18 400
450
500
550
8NES400T
8NES450T
8NES500T
8NES550T
400/500/600/800
A8NES800T1
600
630
700
800
8NES600T
8NES630T
8NES700T
8NES800T
3-Pole NGH3800T33WP18 NGH3800T32WP18 NGH3800T35WP18 NGH3800T36WP18 400
450
500
550
8NES400T
8NES450T
8NES500T
8NES550T
400/500/600/800
A8NES800T1
600
630
700
800
8NES600T
8NES630T
8NES700T
8NES800T
4-Pole 4NGH4800T33WP18 NGH4800T32WP18 400
450
500
550
8NES400T
8NES450T
8NES500T
8NES550T
400/500/600/800
A8NES800T1
600
630
700
800
8NES600T
8NES630T
8NES700T
8NES800T
1200 52-Pole NGH212T33WP08 5NGH212T32WP08 5NGH212T35WP08 5NGH212T36WP08 5 600
630
700
800
12NES600T
12NES630T
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
12NES900T
12NES1000T
12NES1200T
3-Pole NGH312T33WP08 5NGH312T32WP08 5NGH312T35WP08 5NGH312T36WP08 5 600
630
700
800
12NES600T
12NES630T
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
12NES900T
12NES1000T
12NES1200T
4-Pole 4NGH412T33WP08 5NGH412T32WP08 5—— 600
630
700
800
12NES600T
12NES630T
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
12NES900T
12NES1000T
12NES1200T
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
27
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size NG, 1200 Amperes 100 kA at 480 Vac or 415 Vac
Vol. 1, Ref. No. [027]
Table 39. Type NGC Very High Capacity — Ue Max. 690 Vac, 100 kA Icu at 480 Vac or 415 Vac
1For ac use only.
2NG MCCBs are suitable for 40°C or 50°C applications. Order suffix V3 to eliminate standard 40°C labeling.
3Order terminals separately.
4Unprotected left pole neutral. Insert “E” for 100% neutral or “EH” for 60% neutral between “W” and “P” (e.g., NGS412T32EHP08).
5Non-UL listed NG 1250 with 1250 ampere trip unit is also available.
Note: NG MCCBs have metric threading on line and load conductors. Use ND MCCBs if imperial threading is required.
Maximum
Continuous
Ampere
Rating
at 40°C 12
Number
of Poles Circuit Breaker Frame Including Digitrip RMS 310 Electronic Trip Unit with
Adjustable Rating Plugs — Catalog Number 3Interchangeable
Rating Plugs
(Order as Individual
Component)
Included
with Breaker
L Adjustable Long Delay Pickup (By Adjustable Rating Plug)
S Adjustable Short Delay Pickup with Fixed Short Delay Time
(I2t Response) or Adjustable Short Delay Time (Flat Response)
I Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous
G Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response)
LS LSI LSG LSIG Fixed
Rating Plug Adjustable
Rating Plug
Short Time Range
Short Time Delay
Ground Fault Pickup
Ground Fault Delay
2 – 8 x In
2 – 8 x In
I – 300 ms
2 – 8 x In
200 – 1200 A
I – 500 ms
2 – 8 x In
I – 300 ms
200 – 1200 A
I – 500 ms
Ampere
Rating Catalog
Number Adjustable
Ampere
Settings
Catalog Number
800 2-Pole NGC2800T33WP18 NGC2800T32WP18 NGC2800T35WP18 NGC2800T36WP18 400
450
500
550
8NES400T
8NES450T
8NES500T
8NES550T
400/500/600/800
A8NES800T1
600
630
700
800
8NES600T
8NES630T
8NES700T
8NES800T
3-Pole NGC3800T33WP18 NGC3800T32WP18 NGC3800T35WP18 NGC3800T36WP18 400
450
500
550
8NES400T
8NES450T
8NES500T
8NES550T
400/500/600/800
A8NES800T1
600
630
700
800
8NES600T
8NES630T
8NES700T
8NES800T
4-Pole 4NGC4800T33WP18 NGC4800T32WP18 400
450
500
550
8NES400T
8NES450T
8NES500T
8NES550T
400/500/600/800
A8NES800T1
600
630
700
800
8NES600T
8NES630T
8NES700T
8NES800T
1200 52-Pole NGC212T33WP08 5NGC212T32WP08 5NGC212T35WP08 5NGC212T36WP08 5 600
630
700
800
12NES600T
12NES630T
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
12NES900T
12NES1000T
12NES1200T
3-Pole NGC312T33WP08 5NGC312T32WP08 5NGC312T35WP08 5NGC312T36WP08 5 600
630
700
800
12NES600T
12NES630T
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
12NES900T
12NES1000T
12NES1200T
4-Pole 4NGC412T33WP08 5NGC412T32WP08 5—— 600
630
700
800
12NES600T
12NES630T
12NES700T
12NES800T
600/800/
1000/1200
A12NES1200T1
900
1000
1200
12NES900T
12NES1000T
12NES1200T
July 2004
28
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size NG, 1600 Amperes 50 kA at 415 Vac Vol. 1, Ref. No. [028]
Table 40. Type NGS Standard Interrupting Capacity — Ue Max. 690 Vac, 50 kA Icu at 415 Vac
Line and Load Terminals
N-Frame circuit breakers do not include terminals as standard. When copper or
Cu/Al terminals are required, order by catalog number.
Table 41. Line and Load Terminals
5Single terminals individually packed.
6Not suitable with 1600 ampere frame version.
Maximum
Continuous
Ampere
Rating
at 40°C 12
Number
of Poles Circuit Breaker Frame Including Digitrip RMS 310 Electronic Trip Unit and Rating Plugs
L Adjustable Long Delay Pickup (By Adjustable Rating Plug)
S Adjustable Short Delay Pickup with Fixed Short Delay Time
(I2t Response) or Adjustable Short Delay Time (Flat Response)
I Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous
G Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response)
LS LSI LSG LSIG Adjustable
Rating Plug
Short Time Range
Short Time Delay
Ground Fault Pickup
Ground Fault Delay
2 – 8 x In
2 – 8 x In
I – 300 ms
2 – 8 x In
200 – 1200 A
I – 500 ms
2 – 8 x In
I – 300 ms
200 – 1200 A
I – 500 ms
1600 33-Pole
4-Pole 4NGS316T33WP35
NGS416T33WP35 NGS316T32WP35
NGS416T32WP35 NGS316T35WP35
NGS316T36WP35
800/1000/1250/1600
1For ac use only.
2NG MCCBs are suitable for 40°C or 50°C applications. Order suffix V3 to eliminate standard 40°C labeling.
3No UL or CSA label is available for the 1600 ampere frame size.
4Unprotected left pole neutral. Insert “1” for 100% protected neutral or “6” for 60% protected neutral before “WP” suffix (e.g., NGS416T336WP35).
Note: NG 1600 MCCB uses metric threading on line and load conductors. The NG 1600 is not UL or CSA listed.
Maximum
Breaker
Amperes
Terminal
Body
Material
Wire Type Metric Wire
Range mm2AWG Wire
Number of
Conductors
Catalog
Number 5
Standard Cu/Al Pressure-Type Terminals
1250 6Aluminum Cu/Al 120 – 300 4/0 – 500 (3) TA1200NB3M
Optional Copper and Cu/Al Pressure Type Terminals
1250 6Copper Copper 95 – 185 3/0 – 400 (4) T1200NB3M
Base Mounting Hardware
Base mounting hardware is included
with a circuit breaker or molded
case switch.
Table 42. Base Mounting Hardware
Keeper Nut
Not required on N-Frame. Terminals
are threaded.
Handle Extension
Included with breaker. Additional
handle extensions are available.
Table 43. Handle Extension
Interphase Barriers
The interphase barriers provide
additional electrical clearance between
circuit breaker poles for special termi-
nation applications. Barriers are high
dielectric insulating plates that are
installed in the molded slots between
the terminals. (Field installation only.)
Table 44. Interphase Barriers
Number
of Poles Description Catalog
Number
2-, 3-
and 4-pole Imperial Hardware:
.3125 – 18 x 1.25
Pan-Head Steel Screws
and Lock Washers
BMH5
2-, 3-
and 4-pole Metric Hardware: M8
Pan-Head Steel Screws
and Lock Washers
BMH5M
Description Catalog Number
Single Handle Extension HEX5
Description Catalog Number
Interphase Barriers IPB5
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
29
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size RG, 2500 Amperes 65 kA at 480 Vac, 70 kA at 415 Vac — Digitrip 310 Trip Unit
Vol. 1, Ref. No. [029]
RG-Frame, 2500 Amperes — Selection Guide and Ordering Information
Table 45. Type RGH with Digitrip 310 High Interrupting Capacity — Ue Max. 690 Vac, 70 kA Icu at 415 Vac
1For SCR application, use 2000 ampere frame.
2Order terminals separately. Mounting hardware not included.
3Ground fault equipped trip units available with remote indicating panel. Add “R” to catalog number, e.g., “RGH316T35RW.”
4Additional IEC ratings are available on adjustable rating plugs. Contact your Eaton representative.
5Unprotected left pole neutral. Add “P” to catalog number for 100% protected left pole neutral, add “E” for 60% protected, e.g.,
RGH416T33PW”, “RGH416T33EW.”
Note: RG MCCBs have metric threading on line and load conductors. Use RD MCCBs if imperial threading is required.
Maximum
Continuous
Ampere
Rating
at 40°C 1
Number
of Poles Circuit Breaker Frame Including Digitrip RMS 310 Electronic Trip Unit with
Adjustable Rating Plugs — Catalog Number 2Interchangeable
Rating Plugs
(Order as Individual
Component)
Included
with Breaker
L Adjustable Long Delay Pickup (By Adjustable Rating Plug)
S Adjustable Short Delay Pickup with Fixed Short Delay Time
(I2t Response) or Adjustable Short Delay Time (Flat Response)
I Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous
G Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response)
LS LSI LSG 3LSIG 3Fixed
Rating Plug Adjustable
Rating Plug 4
Short Time Range
Short Time Delay
Ground Fault Pickup
Ground Fault Delay
2 – 8 x In
2 – 8 x In
I – 300 ms
2 – 8 x In
200 – 1200 A
I – 500 ms
2 – 8 x In
I – 300 ms
200 – 1200 A
I – 500 ms
Ampere
Rating Catalog
Number Adjustable
Ampere
Settings
Catalog Number
1600 13-Pole RGH316T33WP08 RGH316T32WP08 RGH316T35WP08 RGH316T36WP08 800
1000
1200
1250
16RES08T
16RES10T
16RES12T
16RES125T
800/1000/
1200/1600
A16RES16T1
1400
1500
1600
16RES14T
16RES15T
16RES16T
2000 RGH320T33WP16 RGH320T32WP16 RGH320T35WP16 RGH320T36WP16 1000
1200
1250
20RES10T
20RES12T
A20RES125T
1000/1200/
1600/2000
A20RES20T1
1400
1600
2000
A20RES14T
A20RES16T
A20RES20T
2500 RGH325T33WP39 RGH325T32WP39 RGH325T35WP39 RGH325T36WP39 1200
1250
1600
25RES12T
25RES125T
A25RES16T
1200/1600/
2000/2500
A25RES25T1
2000
2500 A25RES20T
A25RES25T
1600 14-Pole 5RGH416T33WP08 RGH416T32WP08 800
1000
1200
1250
16RES08T
16RES10T
16RES12T
16RES125T
800/1000/
1200/1600
A16RES16T1
1400
1500
1600
16RES14T
16RES15T
16RES16T
2000 RGH420T33WP16 RGH420T32WP16 1000
1200
1250
20RES10T
20RES12T
A20RES125T
1000/1200/
1600/2000
A20RES20T1
1400
1600
2000
A20RES14T
A20RES16T
A20RES20T
2500 RGH425T33WP39 RGH425T32WP39 1200
1250
1600
25RES12T
25RES125T
A25RES16T
1200/1600/
2000/2500
A25RES25T1
2000
2500 A25RES20T
A25RES25T
July 2004
30
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size RG, 2500 Amperes 100 kA at 480 Vac, 415 Vac — Digitrip 310 Trip Unit Vol. 1, Ref. No. [030]
Table 46. Type RGC with Digitrip 310 Very High Interrupting Capacity — Ue Max. 690 Vac, 100 kA Icu at 415 Vac
1For SCR application, use 2000 ampere frame.
2Order terminals separately. Mounting hardware not included.
3Ground fault equipped trip units available with remote indicating panel. Add “R” to catalog number, e.g., “RGH316T35RW.”
4Additional IEC ratings are available on adjustable rating plugs. Contact your Eaton representative.
5Unprotected left pole neutral. Add “P” to catalog number for 100% protected left pole neutral, add “E” for 60% protected, e.g.,
RGH416T33PW”, “RGH416T33EW.”
Note: RG MCCBs have metric threading on line and load conductors. Use RD MCCBs if imperial threading is required.
Table 47. Molded Case Switches
Maximum
Continuous
Ampere
Rating
at 40°C 1
Number
of Poles Circuit Breaker Frame Including Digitrip RMS 310 Electronic Trip Unit with
Adjustable Rating Plugs — Catalog Number 2Interchangeable
Rating Plugs
(Order as Individual
Component)
Included
with Breaker 2
L Adjustable Long Delay Pickup (By Adjustable Rating Plug)
S Adjustable Short Delay Pickup with Fixed Short Delay Time
(I2t Response) or Adjustable Short Delay Time (Flat Response)
I Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous
G Adjustable Ground Fault Pickup with Adjustable Ground Fault Delay (Flat Response)
LS LSI LSG 3LSIG 3Fixed
Rating Plug Adjustable
Rating Plug 4
Short Time Range
Short Time Delay
Ground Fault Pickup
Ground Fault Delay
2 – 8 x In
2 – 8 x In
I – 300 ms
2 – 8 x In
200 – 1200 A
I – 500 ms
2 – 8 x In
I – 300 ms
200 – 1200 A
I – 500 ms
Ampere
Rating Catalog
Number Adjustable
Ampere
Settings
Catalog Number
1600 13-Pole RGC316T33WP08 RGC316T32WP08 RGC316T35WP08 RGC316T36WP08 800
1000
1200
1250
16RES08T
16RES10T
16RES12T
16RES125T
800/1000/
1200/1600
A16RES16T1
1400
1500
1600
16RES14T
16RES15T
16RES16T
2000 RGC320T33WP16 RGC320T32WP16 RGC320T35WP16 RGC320T36WP16 1000
1200
1250
20RES10T
20RES12T
A20RES125T
1000/1200/
1600/2000
A20RES20T1
1400
1600
2000
A20RES14T
A20RES16T
A20RES20T
1600 14-Pole 5RGC416T33WP08 RGC416T32WP08 800
1000
1200
1250
16RES08T
16RES10T
16RES12T
16RES125T
800/1000/
1200/1600
A16RES16T1
1400
1500
1600
16RES14T
16RES15T
16RES16T
2000 RGC420T33WP16 RGC420T32WP16 1000
1200
1250
20RES10T
20RES12T
A20RES125T
1000/1200/
1600/2000
A20RES20T1
1400
1600
2000
A20RES14T
A20RES16T
A20RES20T
Ampere Rating Number of Poles Catalog Number
1600
2000 3-Pole RGK316WK
RGK320WK
1600
2000 4-Pole RGK416WK
RGK420WK
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
31
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size RG, 1250 Amperes — Digitrip 610 & 910 Trip Units
Vol. 1, Ref. No. [031]
Table 48. Type RG with Digitrip 610 and 910
1Order terminals separately. Mounting hardware not included.
2Not to exceed 1200 ampere ground fault pickup.
Note: RG MCCBs have metric threading on line and load conductors. Use RD MCCBs if imperial threading is required.
Maximum
Continuous
Ampere
Rating
at 40°C
Number
of Poles Circuit Breaker Frame Including Digitrip RMS 610 and 910 Electronic Trip Unit with Rating Plugs
Order as Individual Component — Catalog Number 1Digitrip RMS
Interchangeable
Rating Plug
(Order as Individual
Component)
L Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time
S Adjustable Short Delay Pickup with Adjustable Short Delay Time (I2t or Flat Response)
I Adjustable Instantaneous Pickup
G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Time Delay (I2t or Flat Response)
LI LS LSI LIG LSG LSIG Fixed Rating Plug
Long Delay Pickup
Long Delay Time
Short Time Range
Short Time Delay
Instantaneous
Ground Fault Pickup
Ground Fault Delay
0.5 – 1.0 x In
2 – 24 Seconds
2 – 6 x Ir
2 – 6 x M1 & M2
0.5 – I.0n
2 – 24 Seconds
2 – 6 x Ir
100 – 500 ms
0.5 – 1.0 x In
2 – 24 Seconds
2 – 6 x Ir
100 – 500 ms
2 – 6 x M1 & M2
0.5 – 1.0 x In
2 – 24 Seconds
2 – 6 x Ir
2 – 6 x M1 & M2
0.25 – 1.0 x In 2
100 – 500 ms
0.5 – 1.0 x In
2 – 24 Sec.
2 – 6 x Ir
100 – 500 ms
0.25 – 1.0 x In 2
100 – 500 ms
0.5 – 1.0 x In
2 – 24 Seconds
2 – 6 x Ir
100 – 500 ms
2 – 6 x M1 & M2
0.25 – 1.0 x In 2
100 – 500 ms
Ampere
Rating Catalog
Number
Type RGH with Digitrip 610 High Interrupting Capacity — Ue Max. 690 Vac, 70 kA Icu at 415 Vac
1600 3-Pole RGH316T61WP44 RGH316T63WP44 RGH316T62WP44 RGH316T64WP44 RGH316T65WP44 RGH316T66WP44 800
1000
1200
1250
1600
RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A125
RP6R16A160
Includes 1600 A Rating Plug
2000 RGH320T61WP49 RGH320T63WP49 RGH320T62WP49 RGH320T64WP49 RGH320T65WP49 RGH320T66WP49 1000
1200
1250
1600
2000
RP6R20A100
RP6R20A120
RP6R20A125
RP6R20A160
RP6R20A200
Includes 2000 A Rating Plug
2500 RGH325T61WP53 RGH325T63WP53 RGH325T62WP53 RGH325T64WP53 RGH325T65WP53 RGH325T66WP53 1600
2000
2500
RP6R25A160
RP6R25A200
RP6R25A250
Type RGC with Digitrip 610 Very High Interrupting Capacity — Ue Max. 690 Vac, 100 kA Icu at 415 Vac
1600 3-Pole RGC316T61WP44 RGC316T63WP44 RGC316T62WP44 RGC316T64WP44 RGC316T65WP44 RGC316T66WP44 800
1000
1200
1250
1600
RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A125
RP6R16A160
Includes 1600 A Rating Plug
2000 RGC320T61WP49 RGC320T63WP49 RGC320T62WP49 RGC320T64WP49 RGC320T65WP49 RGC320T66WP49 1000
1200
1250
1600
2000
RP6R20A100
RP6R20A120
RP6R20A125
RP6R20A160
RP6R20A200
Includes 2000 A Rating Plug
Type RGH with Digitrip 910 High Interrupting Capacity — Ue Max. 690 Vac, 70 kA Icu at 415 Vac
1600 3-Pole RGH316T91WP44 RGH316T93WP44 RGH316T92WP44 RGH316T94WP44 RGH316T95WP44 RGH316T96WP44 800
1000
1200
1250
1600
RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A125
RP6R16A160
Includes 1600 A Rating Plug
2000 RGH320T91WP49 RGH320T93WP49 RGH320T92WP49 RGH320T94WP49 RGH320T95WP49 RGH320T96WP49 1000
1200
1250
1600
2000
RP6R20A100
RP6R20A120
RP6R20A125
RP6R20A160
RP6R20A200
Includes 2000 A Rating Plug
2500 RGH325T91WP53 RGH325T93WP53 RGH325T92WP53 RGH325T94WP53 RGH325T95WP53 RGH325T96WP53 1600
2000
2500
RP6R25A160
RP6R25A200
RP6R25A250
Includes 2500 A Rating Plug
Type RGC with Digitrip 910 Very High Interrupting Capacity — Ue Max. 690 Vac, 100 kA Icu at 415 Vac
1600 3-Pole RGC316T91WP44 RGC316T93WP44 RGC316T92WP44 RGC316T94WP44 RGC316T95WP44 RGC316T96WP44 800
1000
1200
1250
1600
RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A125
RP6R16A160
Includes 1600 A Rating Plug
2000 RGC320T91WP49 RGC320T93WP49 RGC320T92WP49 RGC320T94WP49 RGC320T95WP49 RGC320T96WP49 1000
1200
1250
1600
2000
RP6R20A100
RP6R20A120
RP6R20A125
RP6R20A160
RP6R20A200
Includes 2000 A Rating Plug
July 2004
32
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size RG, 800 – 2500 Amperes Vol. 1, Ref. No. [032]
Line and Load Terminals
R-Frame circuit breakers use Cu/Al terminals as standard and copper only
terminals as an option. Specify if factory installation is required.
Table 49. Line and Load Terminals
1Order one per pole — single terminals individually packed.
2Order one TA2000RD kit per 3-poles. Catalog number includes bus connection, terminals and
hardware for either line side or load side of 3-pole breaker.
Note: RG MCCBs have metric threading on line and load conductors. Use RD MCCBs if
imperial threading is required.
Figure 10. RD Rear Connector Exploded View
1Order one per pole (or two per pole if line and load terminals are required) — single terminals
individually packed.
Note: RG MCCBs have metric threading on line and load conductors. Use RD MCCBs if
imperial threading is required.
Maximum
Breaker
Amperes
Terminal
Body
Material
Wire
Type Hardware AWG/kcmil
Wire Range/
Number
of Conductors
Metric Wire
Range mm2Catalog
Number
Wire Terminals
1600
1600
2000
Aluminum
Copper
Aluminum
Cu/Al
Cu
Cu/Al
Metric
Metric
Metric
500 – 1000 (4)
1 – 600 (4)
2 – 600 (6)
300 – 500
50 – 300
35 – 300
TA1600RDM 1
T1600RDM 1
TA2000RDM 2
Rear Connectors
2000
2000
2500
Copper
Copper
Copper
Metric
Metric
Metric
B2016RDM 1
B2016RDLM 1
B2500RDM 1
Conductor
(Viewed from Front
of Circuit Breaker)
Conductor
(Viewed from Rear
of Circuit Breaker and
Cut Away for Clarity)
Rear Connector (Cu)
B2016RD
B2016RDL (For 100% Application)
(For 1600 A and 2000 A Frames)
Securing
Hardware
Securing Hardware
Cu Only
Terminal
Catalog
Number
T1600RD 1
(For 1600 A
Frame Only)
Al/Cu
Terminal
Catalog
Number
TA1600RD 1
(For 1600 A
Frame Only)
OR
Figure 11. TA2000RD Wire Terminal
Note: Order one TA2000R0M kit per 3-poles.
Catalog number includes bus connection,
terminals and hardware for either line side
or load side of 3-pole breaker.
Base Mounting Hardware
Supplied by customer.
Handle Extension
Included with breaker. Additional
handle extensions are available.
Table 50. Handle Extension
Description Catalog Number
Single Handle Extension HEX6
NEED ART
FROM PG. 29 OF
PG.29B.01A.T.U
(FEB, 2001)
Breaker Line/Load
Conductors
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
33
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Motor Circuit Protectors
Vol. 1, Ref. No. [033]
Motor Circuit Protectors — Selection Guide and Ordering Information
Table 51. EG-Frame — 600Y/347 Vac Maximum, 250 Vdc Maximum 1
1UL listed for use with Cutler-Hammer Motor Starters.
2Motor FLA ranges are typical. The corresponding trip setting is at
13 times the minimum FLA value shown. Where a 13 times setting is
required for an intermediate FLA value, alternate cam settings and/or
MCP ratings should be used.
3For dc applications, actual trip levels are approximately 40% higher
than values shown.
4Settings above 10xIn are for special applications. Where the ampere
rating of the disconnecting means cannot be less than 115% of the
motor full load ampere rating.
Table 52. JG-Frame — 600 Vac Maximum, 250 Vdc Maximum 5
5UL listed for use with Cutler-Hammer Motor Starters.
Table 53. LG-Frame — 600 Vac Maximum, 250 Vdc Maximum 67
6Equipped with an electronic trip device.
7UL listed for use with Cutler-Hammer Motor Starters.
Table 54. NG-Frame — 600 Vac Maximum 89
8UL listed for use with Cutler-Hammer Motor Starters.
9Equipped with an electronic trip device.
Continuous
Amperes Cam
Setting Motor Full Load
Current Amperes 2MCP Trip
Setting 3MCP Catalog
Number
3 A
B
C
D
E
F
.69 – .91
1.1 – 1.3
1.6 – 1.7
2.0 – 2.2
2.3 – 2.5
– 2.6
9
15
21
27
30
33
HMCPE003A0C
7 A
B
C
D
E
F
1.5 – 2.0
2.6 – 3.1
3.7 – 3.9
4.8 – 5.2
5.3 – 5.7
5.8 – 6.1
21
35
49
63
70
77
HMCPE007C0C
15 A
B
C
D
E
F
3.4 – 4.5
5.7 – 6.8
8.0 – 9.1
10.4 – 11.4
11.5 – 12.6
12.7 – 13.0
45
75
105
135
150
165
HMCPE015E0C
30 A
B
C
D
E
F
3.9 – 9.1
11.5 – 13.7
16.1 – 18.3
20.7 – 22.9
23.0 – 25.2
25.3 – 26.1
90
150
210
270
300
330
HMCPE030H1C
50 A
B
C
D
E
F
11.5 – 15.2
19.2 – 22.9
26.9 – 30.6
34.6 – 38.3
38.4 – 42.1
42.2 – 43.5
150
250
350
450
500
550
HMCPE050K2C
70 A
B
C
D
E
F
16.1 – 30.6
26.9 – 32.2
37.6 – 42.9
48.4 – 53.7
53.8 – 59.1
59.2 – 60.9
210
350
490
630
700
770
HMCPE070M2C
100 A
B
C
D
E
F
23.0 – 30.6
38.4 – 46.0
53.8 – 61.4
69.2 – 76.8
76.9 – 84.5
84.6 – 87.0
300
500
700
900
1000
1100
HMCPE100R3C
100 A
B
C
D
E
F
38.4 – 46.0
57.6 – 65.2
76.9 – 84.5
4
4
4
500
750
1000
1250
1375
1500
HMCPE100T3C
Continuous
Amperes MCP Trip
Range (Amperes) MCP Catalog
Number
250 500 – 1000
625 – 1250
750 – 1500
HMCPJ250D5L
HMCPJ250F5L
HMCPJ250G5L
875 – 1750
1000 – 2000
1125 – 2250
1250 – 2500
HMCPJ250J5L
HMCPJ250K5L
HMCPJ250L5L
HMCPJ250W5L
Continuous
Amperes MCP Trip
Range (Amperes) MCP Catalog
Number
600 1125 – 2250
1500 – 3000
1750 – 3500
HMCPL600L
HMCPL600N
HMCPL600R
2000 – 4000
2250 – 4500
2500 – 5000
3000 – 6000
HMCPL600X
HMCPL600Y
HMCPL600P
HMCPL600M
Continuous
Amperes Cam
Setting Motor Full Load
Current Amperes MCP Trip
Setting MCP Catalog
Number
800 A
B
C
D
E
F
G
123.1 – 184.5
184.6 – 246.1
246.2 – 307.6
307.2 – 369.1
369.2 – 430.7
430.8 – 492.2
492.3 – 553.7
1600
2400
3200
4000
4800
5600
6400
HMCP800X7W
1200 A
B
C
D
E
F
G
184.6 –276.8
276.9 – 369.1
369.2 – 461.4
461.5 – 553.7
553.8 – 646.1
646.2 – 738.4
738.5 – 830.7
2400
3600
4800
6000
7200
8400
9600
HMCP12Y8W
July 2004
34
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
30 mA Ground Fault (Earth Leakage) Modules Vol. 1, Ref. No. [034]
30 mA Ground Fault
(Earth Leakage) Modules
Clockwise from Left: JG, LG, EG
MCCBs Shown with Ground Fault
(Earth Leakage) Modules
Eaton offers a 3- and 4-pole 30 mA
ground fault (earth leakage) protection
module for EG, JG and LG breakers.
The module does not restrict the use
of other breaker accessories. UL-listed
modules are available for JG and LG
MCCBs. The IEC-rated EG module
is side mounted for circuits up to
125 amperes, while the JG and LG
modules are both bottom mounted for
circuits up to 160 and 250 amperes (JG),
or 400 and 630 amperes for the LG.
The module is completely self-contained
since the current sensor, relay and
power supply are located inside the
product. Current pickup settings are
selectable from 0.03 – 10 amperes for
all IEC-rated modules and JG UL-listed
module, and 0.03 – 30 amperes for
the LG UL-listed modules. Time delays
are also selectable from Instantaneous
– 1.0 seconds for 0.10 ampere settings
and above. A current pickup setting
of 0.03 amperes defaults to an Instan-
taneous time setting regardless of
the time dial’s position. Two alarm
contacts come as standard: a 50% pre-
trip and a 100% after trip, both based
only on earth leakage current levels.
Figure 12. UL-Rated LG-Frame Earth Leakage Module Faceplate
Figure 13. IEC-Rated LG-Frame Earth Leakage Module Faceplate
Product Selection
Table 55. EG-Frame Earth Leakage Modules,
IEC (Side Mounted, 230 – 415 Vac, 50/60 Hz)
Table 56. JG-Frame Ground Fault Modules,
UL-Rated (Bottom Mounted,
120 – 480 Vac, 50/60 Hz)
Table 57. JG-Frame Earth Leakage Modules,
IEC (Bottom Mounted, 230 – 415 Vac, 50/60 Hz)
Table 58. LG-Frame Ground Fault Modules,
UL-Rated (Bottom Mounted,
120 – 480 Vac, 50/60 Hz)
Table 59. LG-Frame Earth Leakage Modules,
IEC (Bottom Mounted, 230 – 415 Vac, 50/60 Hz)
Amperes Poles Catalog
Number
125
125 3
4ELESE3125W
ELESE4125W
Amperes Poles Catalog
Number
150
150 3
4ELJBN3150W
ELJBN4150W
250
250 3
4ELJBN3250W
ELJBN4250W
Amperes Poles Catalog
Number
160
160 3
4ELJBE3160W
ELJBE4160W
250
250 3
4ELJBE3250W
ELJBE4250W
Amperes Poles Catalog
Number
400
400 3
4ELLBN3400W
ELLBN4400W
600
600 3
4ELLBN3600W
ELLBN4600W
Amperes Poles Catalog
Number
400
400 3
4ELLBE3400W
ELLBE4400W
630
630 3
4ELLBE3630W
ELLBE4630W
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
35
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Special Features and Accessories
Vol. 1, Ref. No. [035]
Special Features and
Accessories
Internal Accessories
Alarm Lockout
The alarm switches operate when
the circuit breaker is tripped by a short
circuit or overcurrent, but also when
it is tripped by a shunt trip or under-
voltage release.
Auxiliary Switches
Auxiliary switches are used for
signaling and control purposes.
The various functions of the auxiliary
switches (changeover) are shown in
Figure 15.
Shunt Trips
The shunt trip is used for remote
tripping.
The coil of the shunt trip is rated only
for short-time operation.
It is not permissible with the circuit
breaker open to apply a continuous
opening command to the shunt trip
in order to prevent the breaker from
closing. This means that interlocking
circuits with continuous commands
may not be set up with shunt trips.
Undervoltage Releases
The circuit breaker cannot be closed
until the undervoltage release is ener-
gized. If the release is not energized,
the circuit breaker can only perform
an idle switching operation.
Frequent idle switching actions
should be avoided as they shorten the
endurance of the circuit breaker.
Accessory Configurations for EG – RG Circuit Breakers
Figure 14. Internal Accessory Configurations
Figure 15. Contact Making by the Auxiliary
and Alarm Switches as a Function of the
Switching Position of the Circuit Breaker
= For N and R-Frame Circuit Breakers Only
July 2004
36
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Special Features and Accessories Vol. 1, Ref. No. [036]
Special Calibration
Special non-UL listed calibrations
are available for certain ambient
temperatures other than 40ºC and
for frequencies other than 50/60 Hz
or dc. Reduced interrupting ratings
will apply for 400 Hz applications.
50ºC Calibration
Note: Breakers equipped with electronic trip
units can operate reliably in ambient tem-
peratures of 50ºC. Add suffix “V3” to NG
MCCBs to remove standard 40°C labeling.
Add suffix “V” to catalog number
for complete thermal magnetic
breaker when ordering listed ampere
ratings for breakers to be used in 50ºC
ambients. 50ºC ambient MCCBs are
not UL listed.
Contact Eaton for availability.
Moisture-Fungus Treatment
All Cutler-Hammer Circuit Breaker
cases are molded from glass-polyester
which does not support the growth of
fungus. Any parts which are susceptible
to the growth of fungus will require
special treatment.
Order by description.
Table 60. Calibrations and Treatment
Table 61. External Accessories and Test Kit
1Provision only.
2Requires two breakers.
3Contact Eaton for availability of operators for EG- and NG-Frames before December 2004.
4Contact Eaton for catalog numbers.
5Digitrip 310 only.
6Catalog Numbers MTST120V (120 Vac) and MTST230V (230 Vac).
Description Frame
EG JG LG NG RG
Special Calibration ✓✓✓✓✓
Moisture-Fungus Treatment ✓✓✓✓✓
Description Fit
Type Frame
EG JG LG NG RG
External Accessories
Non-Padlockable
Handle Block Field EFHB LKD4
Padlockable
Handle Block Field EFPHB FJPHB LBHP
Padlockable Handle
Block Off-Only Field EFPHBOFF FJPHBOFF LBHPOFF
Padlockable Handle
Lock Hasp Field EFPHL FJPHL LPHL PLK5 HLK6
Padlockable Handle
Lock Hasp Off-Only Field EFPHLOFF FJPHLOFF LPHLOFF
Cylinder Lock Factory Order by Description
Key Interlock Kit 1Field KYKFJ KYKL KYK4 KYK6
Slide Bar Interlock 2Field EFSBI FJSBI SBKL3 SBK5
Walking Beam
Interlock 2Factory FJWBI WBLL3630 WBL5 WBL6
Electrical Operator 3120 Vac EOPEF240C EOPFJ240C EOPLG240C EOP5T07 EOP6T08
240 Vac EOPEF240C EOPFJ240C EOPLG240C EOP5T11 EOP6T11K
380 Vac ————
24 Vdc EOPEF24D EOPFJ24D EOPLG24D EOP5T21 EOP6T19K
48 Vdc EOPEF48D EOPFJ48D EOPLG48D EOP5T22 EOP6T21K
125 Vdc EOPEF240C EOPFJ240C EOPLG240C EOP5T26
Plug-In Adapters 3-Pole PAD3E PAD3J PAD3LG PAD53
4-Pole PAD4E PAD4J PAD4LG PAD54
Rear Connecting Studs Field 4444
Test Kit
Electronic Portable Test Kit 566 STK2 STK2
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
37
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Accessories
Vol. 1, Ref. No. [037]
Table 62. Accessories
1Part number for JG and LG is ALM1M1BJPK.
2Part number for JG and LG is ALM2M2BJPK.
3Part number for JG and LG is AUXALRMJPK.
Description Pole
Location Frame
EG, JG & LG NG RG
Field Fit Kit Catalog Numbers
Alarm Lockout Make/Break Left A1L5LPK
Right ALM1M1BEPK 1A1L5RPK A1L6RPK
2 Make/2 Break Left A2L5LPK
Right ALM2M2BEPK 2A2L5RPK A2L6RPK
Auxiliary Switch 1A, 1B Left A1X5LPK
Right AUX1A1BPK A1X5RPK
2A, 2B Left A2X5LPK
Right AUX2A2BPK A2X5RPK A2X6RPK
3A, 3B Left A3X5LPK
Right A3X5RPK
4A, 4B Left ———
Right A4X6RPK
Auxiliary Switch /Alarm Lockout Left AA115LPK
Right AUXALRMEPK 3AA115RPK
Shunt Trip — Standard 120 Vac Left SNT120CPK SNT5LP11K
Right SNT6P11K
240 Vac Left SNT120CPK SNT5LP11K
Right SNT6P11K
24 Vdc Left SNT060CPK SNT5LP03K
Right SNT6P03K
48 Vdc Left SNT060CPK SNT5LP23K
Right SNT6P23K
380 – 600 Vac Left SNT480APK
Right ———
220 – 250 Vdc or 380 – 440 Vac SNT5LP14K SNT6P14K
480 – 600 Vac SNT5LP18K SNT6P18K
Shunt Trip — Low Energy Left LST5LPK
Right LST6RPK
Undervoltage Release Mechanism 120 Vac Left UVR120APK UVH5LP08K
Right UVH6RP08K
208 – 240 Vac Left UVR240APK UVH5LP11K
Right UVH6RP11K
24 Vdc, Vac Left UVR024CPK UVH5LP21K
Right UVH6RP21K
48 Vdc Left UVR048DPK UVH5LP23K
Right UVH6RP23K
12 Vdc, Vac Left UVR012CPK
Right ———
48 Vac Left UVR048APK UVHLP05K
Right UVHRP05K
120 Vdc Left UVR125DPK UVHLP26K
Right UVHRP26K
220 – 250 Vdc Left UVR250DPK UVHLP28K
Right UVHRP28K
380 – 500 Vac Left UVR480APK UVHLP29K
Right UVHRP29K
525 – 600 Vac Left UVR600APK
Right ———
12 Vdc Left UVHLP20K
Right UVH6RP20K
12 Vac Left UVHLP02K
Right UVH6RP02K
Make
Break
a
b
ST
c
UV
July 2004
38
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Plug-in Blocks and Drawout Cassettes Vol. 1, Ref. No. [038]
Plug-in Blocks
Plug-in adapters simplify installation
and front removal of circuit breakers.
Plug-ins are available for rear connec-
tion applications on 3- and 4-pole
circuit breakers. Trip on drawout
interlock kits are included. Stabs for
EG, JG and LG plug-ins rotate 90° for
flexible installation. Use terminal
shields for IP30 protection.
LG Breaker with Plug-in Block
Product Selection
Table 63. Plug-in Blocks
1Included with plug-in block. Trips the breaker
when breaker is removed from plug-in block.
Drawout Cassette
Drawout Cassette
The Drawout Cassette is currently
for use with the standard 3-pole 65
and 100 kA/480 Vac, 1600 ampere and
2000 ampere RG circuit breakers only.
It consists of two separate components:
the movable mechanism which is
factory mounted to the circuit breaker
frame (shown in photo above) and the
stationary mechanism which is housed
in the cassette and shipped separately.
The drawout mechanism has four
positions.
Connected — The breaker is fully
connected to the primary stabs and
secondary contacts.
Test — The breaker is not connected
to the primary stab but is connected
to the secondary contacts.
Disconnected — Both the primary
stabs and the secondary contacts
are disconnected.
Withdraw — The breaker can
be removed from the cassette.
Breaker
Frame Poles Catalog
Number
EG-, JG- and LG-Frame Plug-in Blocks
EG
EG 3
4PAD3E
PAD4E
JG
JG 3
4PAD3J
PAD4J
LG
LG 3
4PAD3L
PAD4L
Trip-on Drawout Interlock Kit 1
EG
JG
LG
3, 4
3, 4
3, 4
PIILEG
PIILJG
PIILLG
Terminal Shields IP30
EG
EG 3
4EFTS3K
EFTS4K
JG
JG 3
4FJTS3K
FJTS4K
LG
LG 3
4LTS3K
LTS4K
Table 64. RG Drawout Cassette
2List price included in price of the stationary
mechanism.
Movable mechanism must be ordered
with RG circuit breaker and is shipped
mounted to circuit breaker frame.
Stationary mechanism is ordered
separately.
All internal accessories must be factory
installed for use with drawout.
Description Catalog Number
65 kA/480 Vac Version
Movable
Mechanism RD20DOM 2
Stationary
Mechanism RD20DOS (without shutters)
RD20DOSS (with shutters)
100 kA/480 Vac Version
Movable
Mechanism RD20DOM 2
Stationary
Mechanism RD20DOS (without shutters)
RD20DOSS (with shutters)
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
39
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Handle Mechanisms
Vol. 1, Ref. No. [039]
Handle Mechanisms
Overview
Handle mechanisms are used to
operate molded case circuit breakers,
molded case switches and motor
circuit protectors. They are available
in three basic configurations Flange
Mounted, Through-the-Door and
Direct (Close-Coupled) — providing
safe, dependable operation and ease
of installation.
Flange Mounted
Flex Shaft
Through-the-Door
Universal Rotary
Direct (Close Coupled)
Universal Direct
Euro IEC
Handle mechanisms are typically used
on enclosed circuit breakers, control
panels and motor control centers
in many different applications. Eaton
Electrical has a handle mechanism
for virtually any need.
Flange Mounted Handle
Mechanisms
The Flex ShaftE
Flange Mounted handle mechanisms
mount on the flange of an enclosure
door. The Flex Shaft is an extra
heavy-duty mechanism that includes
a flexible shaft in various lengths,
3 feet (0.9 m) through 10 feet (3 m)
for use with various size enclosures.
The Flex Shaft handle will accept up
to three padlock shackles, each with
a maximum diameter of 3/8 inch
(9.5 mm). Can be used with NEMA 12
fabricated enclosures. An optional
handle is available for Flex Shaft
that is suitable for use with NEMA 4
environments.
Flex Shaft comes preset from the
factory, requiring only minor field
adjustments on installation, which
takes about 10 minutes — a significant
time savings compared to installation
of other types of flange handle mecha-
nisms. The Flex Shaft mechanism
also takes up less interior enclosure
space than competitive designs and
the handle fits standard flange cutouts.
Flex Shaft handle can be remotely
mounted from breaker, where an
operator can use it by “funneling”
the cable through conduit.
Flex Shaft is UL listed under File
E64893 and meets CSA requirements.
Note: NEMA 4X handle mechanisms are
available. Add Suffix X to the complete
Catalog Number.
Original narrow handle design
(No C Suffix) is available. Remove C
from Catalog Number.
Note: When selecting the length of
shaft, ensure minimum bending radius
of 4 inches (101.6 mm) is maintained to
operate properly.
The standard method of shipment
includes the mechanism preset at
the factory; however, minor field
adjustments may be required.
Flex Shaft Ordering Information
Table 65. Flex Shaft Ordering Information
Note: Add Suffix L to the complete Catalog Number for 6-inch (152.4 mm) handle.
Flex Shaft Accessories (E- through R-Frame)
Table 66. Standard Door Hardware
(Required Adapter Kit)
Table 67. Door Hardware Adapter Kit
(Required on Standard Door Hardware)
Table 68. NEMA 12 Safety Door
Hardware for Flex Shaft 1
1Customer: Consult with box manufacturer
for correct door hardware and any adapters
required for assembly.
2The 1/4-inch x 1/2-inch (6.35 x 12.7 mm)
standard mill rectangular locking bar is not
supplied with these kits.
3Third roller latch for use with 4- or 6-inch
(101.6 or 152.4 mm) handle when 3 point
latching is required.
Table 69. NEMA — IP Crossover
Breaker
Frame Flexible Shaft Length in Feet (m)
Catalog Number
3 (.9) 4 (1.2) 5 (1.3) 6 (1.8) 7 (2.1) 8 (2.4) 9 (2.7) 10 (3.1)
EG
JG EHMFS03
JHMFS03 EHMFS04
JHMFS04 EHMFS05
JHMFS05 EHMFS06
JHMFS06 EHMFS07
JHMFS07 EHMFS08
JHMFS08 EHMFS09
JHMFS09 EHMFS10
JHMFS10
LG
NG
RG
N/A
N/A
LHMFS04
F5S04CI
F6S04
F5S05CI
F6S05
F5S06CI
F6S06
LHMFS07
N/A
N/A
N/A
N/A
N/A
N/A
LHMFS10
F5S10CI
N/A
Latch Panel Height
Inches (mm) Catalog
Number
2 Point
2 Point
3 Point
Up to 30.00 (762.0)
Up to 40.00 (1016.0)
Over 40.00 (1016.0)
DH1R
DH2R
DH3R
Description Catalog Number
Door Hardware
Adapter Kit AMTDHA
Handle Length
in Inches (mm) Catalog
Number 2
4.00 (101.6)
6.00 (152.4) C361KJ4
C361KJ6
Roller Latch 3C361KR
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CB-2
NEMA
Type IP
Type
1
3R
12
4/4X
IP20
IP55
IP54
IP66
July 2004
40
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Handle Mechanisms Vol. 1, Ref. No. [040]
Through-the-Door Handle
Mechanisms
Universal Rotary
The Cutler-Hammer Universal Rotary
is suitable for use with NEMA 12
enclosure types. An optional NEMA
4/4X handle mechanism is also avail-
able. All rotary handle mechanisms
include a handle “Lock Off,” to prevent
turning the breaker ON while in the
OFF position. All Rotary handles indi-
cate ON/OFF/Tripped/Reset positions,
however, Universal Rotary has
the added feature of international
markings for ON (I) and OFF (O).
The Universal Rotary is made of
molded material.
The Universal Rotary mechanisms
for EG, JG and LG MCCBs can be
operated by hand with the door open
or “locked off” to prevent operation
with the door open.
For the NG-Frame MCCBs, a
Cutler-Hammer Rotary with a metal
handle (Table 71) is also available.
Table 70. Universal Rotary Ordering
Information
1Complete catalog number includes handle,
mechanism, shaft and mounting hardware.
2Add suffix “X” for NEMA 4/4X.
Table 71. Cutler-Hammer Rotary Ordering
Information — NG-Frame
3Complete catalog number includes handle,
mechanism, shaft and mounting hardware.
Shaft Length
in Inches (mm) Handle
Color Complete
Catalog Number 12
EG-Frame
6.00 (152.4)
12.00 (304.8)
24.00 (609.6)
Black
Black
Black
EHMVD06B
EHMVD12B
EHMVD24B
6.00 (152.4)
12.00 (304.8)
24.00 (609.6)
Red
Red
Red
EHMVD06R
EHMVD12R
EHMVD24R
JG-Frame
6.00 (152.4)
12.00 (304.8)
24.00 (609.6)
Black
Black
Black
FJHMVD06B
FJHMVD12B
FJHMVD24B
6.00 (152.4)
12.00 (304.8)
24.00 (609.6)
Red
Red
Red
FJHMVD06R
FJHMVD12R
FJHMVD24R
LG-Frame
6.00 (152.4)
12.00 (304.8)
24.00 (609.6)
Black
Black
Black
KLHMVD06B
KLHMVD12B
KLHMVD24B
6.00 (152.4)
12.00 (304.8)
24.00 (609.6)
Red
Red
Red
KLHMVD06R
KLHMVD12R
KLHMVD24R
NG-Frame
6.00 (152.4) Black HMVD5B
RG-Frame
9.00 (235.0) Black HMVD6B
Shaft
Length in
Inches (mm)
Handle
Color Complete
Catalog Number 3
NEMA
1, 3R, 12 NEMA
4/4X
6.00 (152.4)
12.00 (304.8)
16.00 (406.4)
24.00 (609.6)
Black
Black
Black
Black
WHM5R06
WHM5R12
WHM5R16
WHM5R24
WHM5R06X
WHM5R12X
WHM5R16X
WHM5R24X
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
41
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Handle Mechanisms
Vol. 1, Ref. No. [041]
Direct (Close-Coupled)
Handle Mechanisms
Universal Direct (EG – LG)
Direct (Close-Coupled) Handle
Mechanisms mount directly to the
circuit breaker. They are used in shal-
low enclosures where the standard
variable depth Through-the-Door type
mechanism is not practical or cannot
be used. They are typically for applica-
tions where high volume, standardized
enclosures are being fabricated.
The Universal Direct handle mecha-
nism is designed exclusively for the
new Cutler-Hammer EG, JG and
LG circuit breakers. It is available
as standard with a door interlock to
prevent opening the enclosure while
the circuit breaker is in the ON
position. It is also available without
a door interlock.
The Universal Direct handle mecha-
nism is UL 489 listed, IEC 60947-1/2
and meets CSA requirements.
The Euro IEC Direct handle mechanism
is designed for NG and RG MCCBs.
The Euro IEC Direct handle mechanism
is 60947-112.
Table 72. Universal Direct Ordering Information
Table 73. Euro IEC Direct Ordering Information
Frame White Handle Color Red Handle Color
with Interlock without Interlock without Interlock
Catalog Number
EG
JG
LG
EHMCCBI
JHMCCBI
LHMCCBI
EHMCCB
JHMCCB
LHMCCB
EHMCCR
JHMCCR
LHMCCR
Frame Catalog Number
Black Handle
NG
RG HMVD5B
HMVD6B
July 2004
42
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Vol. 1, Ref. No. [042]
Time-Current Curves
Tripping Characteristics
The operating values specified for
the inverse time overcurrent releases
(thermal overload releases, “a”
releases) are mean values of the scat-
ter bands of all setting ranges from the
cold state and with uniform current
loading of the conducting paths.
The tripping characteristics of the
instantaneous (electromagnetic) short
circuit releases (“n” releases) are
based on the rated phase current In
which in the case of circuit breakers
with adjustable thermal overload
releases is also the upper value of the
setting range. With a lower setting
current, a correspondingly higher
multiple is obtained for the operating
current of the “n” release.
Figure 16. Tripping Time Characteristics
(Thermal Memory)
015
Type EG
Tripping characteristics of EG
circuit breakers for plant protection,
“n” release fixed setting = 400 – 600 for
breaker 15 – 45 A; over 50 A = 10x In.
Figure 17. EG Time Current Curve
Type JG
Tripping characteristics of JG
circuit breakers for plant protection,
“n” release adjustable.
Figure 18. JG Time Current Curve for
Thermal Magnetic Trip Units
Type LG
Figure 19. LG Time Current Curve for Thermal Magnetic Trip Units
100246810124681022468103
10000
5000
3000
2000
1000
500
300
200
100
50
30
20
10
5
3
2
1
.5
.3
.2
.1
.05
.03
.02
.01
.005
.003
.002
.001
TIME IN SECONDS
CURRENT IN MULTIPLES OF In
(a)
50-125
20
25
30-3215-16
35
40
45(c)(d)
Max. Trip Time
Min. Trip
Time
100246810124681022468103
10000
5000
3000
2000
1000
500
300
200
100
50
30
20
10
5
3
2
1
.5
.3
.2
.1
.05
.03
.02
.01
.005
.003
.002
.001
TIME IN SECONDS
CURRENT IN MULTIPLES OF In
(b)
10XIn
(a)
5XIn
Max. Trip Time
Min.
Trip
Time
(c)(d)
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
43
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Vol. 1, Ref. No. [043]
Figure 20. LG Electronic Trip Unit Long Delay Response and Short Delay with I2T Response Curve
July 2004
44
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Vol. 1, Ref. No. [044]
Figure 21. LG Electronic Trip Unit Long Delay Response and Short Delay with Flat Response Curve
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
45
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Vol. 1, Ref. No. [045]
Figure 22. LG Electronic Trip Unit Ground Fault Delay Response Curve
July 2004
46
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Vol. 1, Ref. No. [046]
Type NG
Tripping characteristics of NG
circuit breakers with solid-state
overcurrent release.
Working Temperature Range
The tolerance bands shown are appli-
cable to an ambient temperature range
of -5 to +60°C at the circuit breaker.
Figure 23. NG Time Current Curve for Digitrip 310 Trip Unit
123456810
15Xlr
7200
1000
500
200
100
50
20
10
5
2
1
.5
.2
.1
.05
.02
.01
.005
TIME IN SECONDS
CURRENT IN MULTIPLES OF In
1.5 10 15 20 30 40 60 80 100 200
kA
Setting for ld
as Multiples of lr
(7x lr Not Shown)
2X
3X
4X
5X6X
8X
7 X
Notes:
Inverse-time overload release “a”
lr Set current (adjustable)
Short time delayed short circuit release
ld Tripping current (adjustable)
td Delay time (adjustable)
Instantaneous short circuit release “n”
li Tripping current (fixed setting)
td
300 ms
200 ms
100 ms
n
s
a
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
47
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Vol. 1, Ref. No. [047]
Figure 24. NG Ground Fault Delay Response Curve for Digitrip 310 Trip Unit
Series G NG Frame Circuit Breakers
The NES Digitrip RMS 310 Trip Units are AC only devices that employ microprocessor based
technology that provides true RMS current sensing means for proper correlation with thermal
characteristics of conductors and equipment. They are used with Circuit Breaker Types NGS,
NGH and NGC.
Curve accuracy applies from -20°C to +55°C ambient.
Digitrip RMS 300 trip units are suitable for functional field testing with Test Kit Cat. No. STK2.
For field testing using primary injection methods, follow NEMA publication AB-4.
July 2004
48
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Vol. 1, Ref. No. [048]
Type RG
Tripping characteristics of RG
circuit breakers with solid-state
overcurrent release.
Working Temperature Range
The tolerance bands shown are appli-
cable to an ambient temperature range
of -5 to +60°C at the circuit breaker.
Figure 25. RG Time Current Curve for Digitrip 310 Trip Unit
123456810
15Xlr
7200
1000
500
200
100
50
20
10
5
2
1
.5
.2
.1
.05
.02
.01
.005
TIME IN SECONDS
CURRENT IN MULTIPLES OF In
1.5 10 15 20 30 40 60 80 100 200
kA
Setting for ld
as Multiples of lr
(7X lr Not Shown)
2X
3X
4X
5X6X
8X
7 X
td
300 ms
200 ms
100 ms
n
s
a
Notes:
Inverse-time overload release “a”
lr Set current (adjustable)
Short time delayed short circuit release
ld Tripping current (adjustable)
td Delay time (adjustable)
Instantaneous short circuit release “n”
li Tripping current (fixed setting)
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
49
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Vol. 1, Ref. No. [049]
Figure 26. RG Ground Fault Delay Response Curve for Digitrip 310 Trip Unit
• •
Series G RG Frame Circuit Breakers
Equipped with Type Digitrip RMS 310 Trip Units for Ground Fault Protection.
They are used with Circuit Breakers Types RGH and RGC.
Curve accuracy applies from -20°C to +55°C ambient.
Digitrip RMS 310 trip units are suitable for functional field testing with test kit Cat. No. STK2.
For field testing using primary injection methods, follow NEMA publication AB-4.
July 2004
50
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Sizes EG through RG Vol. 1, Ref. No. [050]
Current Limiting Curves
Current Limiting Characteristics and Maximum I2t Values
Type EG/JG/LG
Figure 27. Current Limiting Characteristics
for EG to LG, 50/60 Hz 380/415/480 Vac
Type EG/JG/LG
Figure 28. Current Limiting Characteristics for
EG to LG, 50/60 Hz 600/660/690 Vac
Type EG/JG/LG
Figure 29. Maximum I2t Values for EG to LG,
50/60 Hz 380/415/480 Vac
Type EG/JG/LG
Figure 30. Maximum I2t Values for EG to LG,
50/60 Hz 600/660/690 Vac
Type NG/RG
Figure 31. Current Limiting Characteristics Ip
for NG to RG, 50/60 Hz 380/415/480 Vac
Type NG/RG
Figure 32. Maximum I2t Values for NG to RG,
50/60 Hz 600/660/690 Vac
0.3
5 7 10 20 30 50 kA 100
200
kA
100
80
60
40
20
10
8
6
4
2
CUT-OFF CURRENT ID
SHORT CIRCUIT CURRENT ISrms
0.2
E
J
L
cos = 0.25
5 7 10 20 30 50 kA 100
200
kA
100
80
60
40
20
10
8
6
4
2
CUT-OFF CURRENT I
D
SHORT CIRCUIT CURRENT I
Srms
0.3
0.2
E
J
L
cos = 0.25
5 7 10 20 30 50 kA 100
100
80
60
40
20
10
6
4
2
1
I
2
t
VALUE X10
5
SHORT CIRCUIT CURRENT I
Srms
L
8
J
E
5 7 10 20 30 50 kA 100
100
80
60
40
20
10
6
4
2
1
I
2
t
VALUE X10
5
SHORT CIRCUIT CURRENT I
Srms
L
8
A
2
s
J
E
5 7 10 20 30 50 kA 100
200
kA
100
80
60
40
20
10
8
6
4
2
CUT-OFF CURRENT ID
SHORT CIRCUIT CURRENT ISrms
0.3
0.2 R
N
0.5
cos = 0.25
5 7 10 20 30 50 kA 100
100
80
60
40
20
10
6
4
2
1
I2t VALUE X106
SHORT CIRCUIT CURRENT ISrms
8
A2s
N
R
R
N
Notes:
50/60 Hz 380/415 VAC
50/60 Hz 660/690 VAC
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
51
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Sizes EG through JG
Vol. 1, Ref. No. [051]
Dimensions
Figure 33. EG-Frame — Dimensions in Inches (mm)
Figure 34. JG-Frame — Dimensions in Inches (mm)
Front View 3-PoleFront Cover CutoutSide View
2.77
(70.4)
3.03
(77.0) 5.50
(139.7)
0.14 (3.6) R1.85
(47.0)
1.30 Dia.
(33.0) 0.94 (23.9)
0.90
(22.9)
0.47 (11.9)
C
L
C
L
C
3.00
(76.2)
Handle
C
L
C
L
C
Breaker
Front View 3-Pole
Front Cover CutoutSide View
4.13
(104.9)
1.25 (31.8)
0.63 (16.0)
0.19 (4.8) R
3.44
(87.4)
7.00
(177.8)
3.95
(100.3)
4.00
(101.6)
3.06
(77.7)2.05 (52.1)
1.06 (27.0)
0.50
(12.7)
C
L
C
L
C
Handle
July 2004
52
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Sizes LG through RG Vol. 1, Ref. No. [052]
Figure 35. LG-Frame — Dimensions in Inches (mm)
Note: TA63IL, T63IL, T632L, TA632L terminals add 1.19 inches (30.2 mm) to line or load side of LG. LTS3K or LTS4K terminal covers add
2.13 inches (54.1 mm) to line or load side of LG.
Figure 36. NG-Frame — Dimensions in Inches (mm)
5.58
10.13
(257.3)
4.06
(103.1)
5.48
(139.2)
1.92
(48.8)
2.43
(61.7)
3.16
(80.3)
R .25
(6.4)
2.00
(50.8)
2.69
(68.3)
5.38
(136.7)
BREAKER
4-Pole
9.25
(235.0)
C
L
C
L
C
Breaker
Front View 3-Pole
Front Cover Cutout
16.00
(406.4)
3.44 (87.4)
0.25 (6.4) R
Side View
C
L
C
L
C
Handle
5.50
(139.7)
8.25
(209.6)
1.72 (43.6)
3.81
(96.7)
1.50 (38.1)
6.38
(162.1)
3.19 (81.0)
0.19 (4.8) R
July 2004
PG01200002E For more information visit: www.EatonElectrical.com
53
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Frame Size RG
Vol. 1, Ref. No. [053]
Figure 37. RG-Frame — Dimensions in Inches (mm)
14.50
(368.3)
7.25
(184.2)
(129.5)(196.9)
0.16 R
(4.1)
Front View 3-Pole
Front Cover Cutout
C
L
Breaker
16.00
(406.4)
8.25
(209.6)
15.50
(393.7)
13.13
(333.5)
6.57
(166.9)
(246.4)15.00
(381.0)
4 Holes
0.44 Dia.
(11.2)
C
L
Handle
13.00
(330.2)
2.25 (57.2)
Tee
Connectors
May Be
Rotated 90
6.75
(171.5)
9.00
(228.6)
Side View
.44 R
(11.2)
5.10
9.70
7.75
July 2004
54
For more information visit: www.EatonElectrical.com PG01200002E
Series G Molded Case Circuit Breakers
15 – 2500 Amperes for UL, CSA & IEC Applications
Vol. 1, Ref. No. [054]
This page intentionally left blank.