639
AQ-E
RELAYS
AQ-E SOLID STATE RELAY
28.0
1.102
15.0
.591
5.0
.197
mm inch
FEATURES
1. Conforms to European safety stan-
dards (VDE0110)
dielectric distance between input and out-
put
• Creepage distance: Min. 3.0 mm
• Clearances distance: Min. 2.5 mm
2. The small-sized slim type
28 mm (L)
×
5 mm (W)
×
15 mm
1.063 inch (L)
×
.197 inch (W)
×
.591 inch
permits high density mounting to PC
board
3. High dielectric strength: 2,500V AC
(between input and output)
4. Two load types available:
DC output type (3A)
AC output type (1A)
5. Zero-cross type are availale (AC
type)
The zero-cross type generates minimal
noise
6. Snubber circuit integrated (AC type)
The snubber circuit is integrated to pre-
vent malfunction caused b y the r apid rise
of voltage on the output side, such as in-
ductive load and current.
TYPES
Type Load voltage Input voltage Part No.
AC output 75 to 250 V AC 5 V DC AQE12105
12 V DC AQE12112
24 V DC AQE12124
DC output 3 to 60 V DC 5 V DC AQE34205
12 V DC AQE34212
24 V DC AQE34224
TYPICAL APPLICATIONS
• Interface relays for programmable controllers
• Industrial equipment
Timers and counters
• Air conditioners
ORDERING INFORMATION
Ex.
Load current Load voltage
1: 1 A
3: 3 A 2: 75 to 250 V AC
4: 3 to 60 V DC
Type
1: AC output (Zero-cross)
2: DC output
(Note) Standard packing: Carton 20 pcs., Case 1,000 pcs.
Input voltage
05: 5 V DC
12: 12 V DC
24: 24 V DC
AQE 12105
Pending
UL CSA VDE
Pending Pending
AQ-E
640
SPECIFICATIONS
Ratings (at 20
°
C 68
°
F, Input voltage ripple: 1% or less)
Characteristics (at 20
°
C 68
°
F, Input voltage ripple: 1% or less)
Item Type AC output DC output Remarks
Part No. AQE12105 AQE12112 AQE12124 AQE34205 AQE34212 AQE34224
Input
side
Input voltage 4 to 6 V DC 9.6 to 14.4 V
DC 21.6 to 26.4
V DC 4 to 6 V DC 9.6 to 14.4
V DC 21.6 to 26.4
V DC
Input impedance Approx. 0.5k
Approx. 1.3k
Approx. 3k
Approx. 0.5k
Approx. 1.3k
Approx. 3k
Drop-out volt-
age, min. 0.5 V DC 1.2 V DC 2.4 V DC 0.5 V DC 1.2 V DC 2.4 V DC
Reverse voltage 3 V
Load
side
Max. load current 1 A AC 3 A DC
Load voltage 75 to 250 V AC 3 to 60 V DC
Frequency 45 to 65 Hz
Non-repetitive
surge current 20 A 15 A AC: In one cycle at 60 Hz
DC: 10 ms
Max. "OFF-state"
leakage current 1.5 mA (applied 200 V) 10
µ
A
Max. "ON-state"
voltage drop 1.6 V 0.3 V at Max. carrying current
Min. load curent 20 mA 1 mA
OFF state dV/dt 50 V/
µ
s—
Max. operating
speed 0.5cps.
at rated operating voltage,
rated load voltage and current
Item AC output DC output Remarks
Operate time max. (1/2 cycle of voltage sine wave) + 1 ms 2 ms
Release time, max. (1/2 cycle of voltage sine wave) + 1 ms 0.4 ms
Insulation resistance, min. 10
9
between input and output Using 500 V DC megger
Breakdown voltage 2,500 Vrms between input and output Initial for 1 min.
Vibration
resistance Functional 10 to 55 Hz double amplitude of 1.5 mm 1 hour for X, Y, Z axes
Destructive 10 to 55 Hz double amplitude of 1.5 mm 10 min. for X, Y, Z axes
Shock
resistance Functional Min. 490 m/s
2
{50 G} 5 times each for X, Y, Z axes
Destructive Min. 490 m/s
2
{50 G} 4 times each for X, Y, Z axes
Ambient temperature –30
°
C to +80
°
C –22
°
F to +176
°
F
Storage temperature –30
°
C to +100
°
C –22
°
F to +212
°
F
Operational method Zero-cross (Turn-ON and Turn-OFF)
REFERENCE DATA
1. Load current vs. ambient temperature 2.-(1) Non-repetitive surge current vs. carrying
time (AC output) 2.-(2) Non-repetitive surge current vs . carrying
time (DC output)
0.5
1.5
1.0
2.0
3.5
3.0
2.5
00–30 20 40 60 80
Ambient temperature, °C
Load current, A
AC type
DC type
0
10
20
30
1 2 3 4 5 7 10 20 30
4050 70 100
No. of cycles at 60 Hz
Non-repetitive surge current, A
0
10
5
20
15
10 100 1,000
Carrying time, ms
Non-repetitive surge current, A
AQ-E
641
3. Input v oltage vs . input current char acteristics 4.-(1) Load current vs. ambient temperature
characteristics for adjacent mounting
(AC output)
4.-(2) Load current vs. ambient temperature
characteristics for adjacent mounting
(DC output)
5
10
15
20
25
30
10502015 25 30
Input voltage, V
Input current, mA
(5 V type) (12 V type) (24 V type)
1.2
1.0
0.8
0.6
0.4
0.2
0200–20 40 60 80 100
Ambient temperature, °C
=15 mm
.591 inch
=10 mm
.394 inch
=5 mm
.197 inch
= Adjacent mounting pitch
Load current, A
3.5
3.0
2.5
2.0
1.5
0.5
1.0
0200-20 40 60 80 100
=15 mm
=10mm
=5mm
Ambient temperature, °C
.591 inch
.394 inch
.197 inch
= Adjacent mounting pitch
Load current, A
DIMENSIONS
mm inch
General tolerance:
±
0.5
±
.020
1.2 .047
5.0
.197 28.0 max.
1.102 max.
1.9
.075
15.0 max.
.591 max.
0.5
.020
.020±.004
0.5±0.1 2-.020+.008
–.004
2-0.5+0.2
–0.1
.149±.012
3.78±0.3
2-.039±.004
2-1.0±0.1
±.012
.843 ±0.3
21.42 .198±.012
5.04±0.3 3.5±0.5
.138±.020
Mounting hole location (Bottom view)
Tolerance:
±
0.1
±
.004
Schematic
AC type
DC type
21.42
.843
5.04
.198 1.9
.075
3.78
.149
2-1.6 dia.
2-.063 dia.
2-1.2 dia.
2-.047 dia.
1.2
.047
Output
+
Input
Input Output
–+ +
For Cautions for Use, see Technical Information
9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.