Type: DILM12-01(24VDC) Article No.: 276880 Ordering information Rated operational current AC-3 400 V Ie A 12 Max. rating for three-phase motors, 50 - 60 Hz AC-3 230 V P kW 3.5 Max. rating for three-phase motors, 50 - 60 Hz AC-3 400 V P kW 5.5 Max. rating for three-phase motors, 50 - 60 Hz AC-3 690 V P kW 6.5 Max. rating for three-phase motors, 50 - 60 Hz AC-4 230 V P kW 2 Max. rating for three-phase motors, 50 - 60 Hz AC-4 400 V P kW 3 Max. rating for three-phase motors, 50 - 60 Hz AC-4 690 V P kW 4.4 Ith = Ie A 20 Conventional thermal current I th = I e AC-1 Open For use with DILA-XHI(V).. General Standards IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical AC operated DC operated Operations x 106 10 Operations 106 10 x Operating frequency, mechanical AC operated Operations/h 9000 DC operated Operations/h 9000 Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclical, to IEC 60068-2-30 Climatic proofing Ambient temperature Open 1 C -25/60 Enclosed C -25/40 Storage C -40/80 Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock, 20 ms Main contacts Make contact g 10 Auxiliary contacts Make contact g 7 Break contact g 5 Protection type IP20 Protection against direct contact when actuated from front (IEC 536) Finger- and back-of-hand proof Weight AC operated kg 0,23 DC operated kg 0,28 Terminal capacity Main cable Solid mm2 1 x (0.75 - 4) 2 x (0.75 - 2.5) Flexible with ferrule mm2 1 x (0.75 - 2.5) 2 x (0.75 - 2,5) Solid or stranded AWG 18 - 14 Anschlussschraube Hauptleiter Tightening torque M3.5 Nm 1.2 Solid mm2 1 x (0.75 - 4) 2 x (0.75 - 2.5) Flexible with ferrule mm2 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) Solid or stranded AWG 18 - 14 Terminal capacity Control circuit cables Anschlussschraube Hilfsleiter Tightening torque M3.5 Nm 1.2 Pozidriv screwdriver Size 2 Standard screwdriver mm 0.8 x 5.5 1x6 Pozidriv screwdriver Size 2 Standard screwdriver mm 0.8 x 5.5 1x6 Tool Main cable Control circuit cables Terminal capacity Main cable Solid mm2 0.75 - 2.5 flexible mm2 0.75 - 2.5 flexible with ferrules mm2 0.75 - 2.5 Solid or stranded AWG 18 - 14 mm2 0.75 - 2.5 Terminal capacity Control circuit cables Solid 2 Flexible mm2 0.75 - 2.5 Flexible with ferrule mm2 0.75 - 2.5 Solid or stranded AWG 18 - 14 Tool Stripping length mm 10 Screwdriver blade width mm 3,5 Main conducting paths Rated impulse withstand voltage Uimp V AC Overvoltage category/pollution degree 8000 III/3 Rated insulation voltage AC Ui V AC 690 Rated operational voltage Ue V AC 690 between coil and contacts V AC 400 between the contacts V AC 400 A 144 Safe isolation to VDE 0106 Part 101 and Part 101/A1 Making capacity (cos O to IEC/EN 60947) up to 690 V Breaking capacity 220/230 V A 120 380/400 V A 120 500 V A 100 660/690 V A 70 Component lifespan AC-3/AC-4 Tripping characteristics Maximum operating frequency AC-1; 400 V Ie Ops/h 800 AC-3; 400 V Ie Ops/h 1000 AC-4; 400 V Ie Ops/h 300 400 V gG/gL 500 V A 20 690 V gG/gL 690 V A 20 400 V gG/gL 500 V A 35 690 V gG/gL 690 V A 25 at 40 C Ith A 22 at 50 C Ith A 21 at 55 C Ith A 21 at 60 C Ith A 20 Enclosed Ith A 18 Short-circuit rating Short-circuit protection Maximum fuse Type "2" coordination Type "1" coordination AC AC-1 duty conv. therm. current 3-pole 50 - 60 Hz open 3 Conventional free air thermal current, 1-pole open Ith A 50 Enclosed Ith A 45 220/230 V Ie A 12 240 V Ie A 12 380/400 V Ie A 12 415 V Ie A 12 440V Ie A 12 500 V Ie A 10 660/690 V Ie A 7 220/230 V P kW 3,5 240V P kW 4 380/400 V P kW 5,5 415 V P kW 7 440 V P kW 7,5 500 V P kW 7 660/690 V P kW 6,5 220/230 V Ie A 7 240 V Ie A 7 380/400 V Ie A 7 415 V Ie A 7 440 V Ie A 7 500 V Ie A 6 660/690 V Ie A 5 220/230 V P kW 2 240 V P kW 2,2 380/400 V P kW 3 415 V P kW 3,4 440 V P kW 3,6 500 V P kW 3,5 660/690 V P kW 4,4 60 V Ie A 20 110 V Ie A 20 220 V Ie A 15 440 V Ie A 1,3 AC-3 duty Rated operational current AC-3 open, 50 - 60 Hz, 3-pole Motor rating AC-4 duty Rated operational current AC-4 open, 50 - 60 Hz, 3-pole Motor rating DC of three-phase capacitors open DC-1 operation DC-3 operation 4 60 V Ie A 20 110 V Ie A 20 220 V Ie A 1,5 440 V Ie A 0,2 60 V Ie A 20 110 V Ie A 20 220 V Ie A 1,5 440 V Ie A 0,2 Current heat loss at Ith W 4,7 Current heat loss at Ie to AC-3/400 V W 1,1 Impedance per pole m& 2,5 Pick-up x Uc 0,8 - 1,1 Abfall x Uc 0,3 - 0,6 Pick-up x Uc 0,8 - 1,1 Abfall x Uc 0,15-0,6 50 Hz Pick-up VA 24 50 Hz Pick-up W 19 50 Hz Sealing VA 4 50 Hz Sealing W 1,2 60 Hz Pick-up VA 29 60 Hz Pick-up W 23 60 Hz Sealing 60 Hz Sealing VA 1,3 50/60 Hz Pick-up VA 28 26 50/60 Hz Pick-up W 22 21 50/60 Hz Sealing VA 4,6 3,9 50/60 Hz Sealing W 1,4 1,2 DC operated Pick-up W 4.5 DC operated Sealing W 4.5 % DF 100 DC-5 operation Current heat loss (3-pole) Magnet systems Voltage tolerance AC operated AC operated Drop-out voltage AC operated Drop-out voltage AC operated DC operated DC operated DC operated DC operated Power consumption of the coil in a cold state and 1.0 x Uc Duty factor Switching times at 100 % Uc (approximate values) Main contacts AC operated 5 4,4 Closing delay ms 20 Opening delay ms 15 DC operated Closing delay ms 35 Opening delay ms 15 Arcing time ms 10 Electromagnetic compatibility (EMC) Emitted interference to EN 60947-1 Interference immunity to EN 60947-1 Mounting position Mounting position, AC- and DC operated Moeller GmbH, Hein-Moeller-Str. 7-11, D-53115 Bonn E-Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net Copyright 2005 by Moeller GmbH. Subject to modifications. HPL-C2005GB-INT V3.0 6